ORG 75 Membrane Clean MC Acid Cleaner - a highly acidic liquid cleaner developed for effective cleaning of reverse osmosis (RO), nanofiltration (NF), ultrafiltration (UF), and microfiltration (MF) membrane systems that are Acid-Tolerant.
Its formulation is designed to dissolve inorganic scales, metallic hydroxides, and other acid-soluble foulants, restoring membrane performance and extending membrane life.
Key Areas of Application of Membrane Cleaning Acidic Cleaners
- Cleaning of acid-tolerant RO, NF, UF, and MF membranes.
- Removal of calcium carbonate, barium sulfate, strontium sulfate, and iron hydroxide scales.
- Preventive maintenance to minimize pressure drop and restore normalized flow.
- Suitable for use in industrial, municipal, and desalination plants.
Usage Guide of Acidic Membrane Cleaner 75
- Use RO permeate or deionized water for dilution.
- Recommended working concentration: *0.3% - 0.5% v/v (≈ 3 L of RXSOL ORG 75 Membrane Cleaner in 1000 L of water).*
- Flush the membrane system with RO permeate or DI water to remove feedwater.
- Isolate the system and drain as required.
- Prepare the cleaning solution in the CIP (Cleaning-in-Place) tank at * 0.3% v/v.
- Mix gently until homogeneous.
- Circulate the solution through the membrane system for 30–60 minutes.
- Maintain flow rates recommended by the membrane manufacturer.
- Keep temperature below 35 °C (95 °F) for safe cleaning.
- Stop circulation and allow the membranes to soak for 1–2 hours.
- Restart circulation for an additional 15–20 minutes.
- Thoroughly flush the system with RO permeate or DI water until the rinse water pH is close to feedwater level.
- Resume normal operation only after confirming system stabilization.
- Normalized flow decreases by 10–15%, or
- Differential pressure increases by 15–20%.
- Do not exceed recommended dosage unless advised.
- Always check membrane manufacturer’s chemical tolerance guidelines (pH, temperature, compatibility).
- Dispose of spent solution in compliance with local environmental regulations.
*NOTE: Dosage entirely depends on the system condition and heaviness of scale deposit. Dosage can vary 2-5% also.
| Parameter | Value |
|---|---|
| Appearance | Clear, colorless to slightly hazy liquid |
| Odor | Mild, acidic |
| pH (1% solution) | < 2 |
| Specific Gravity (25 °C) | ~ 1.20 – 1.25 g/cm³ |
| Solubility | Completely miscible in water |
| Flash Point | Non-flammable |
| Boiling Point | > 100 °C |
| Freezing Point | ~ –10 °C |
- Highly Effective Cleaning – Rapidly dissolves inorganic scales, carbonate deposits, and metallic hydroxides to restore membrane performance.
- Low Dosage Requirement (0.3%) – Achieves excellent results at very low concentrations, reducing chemical consumption and cost.
- Membrane Compatible – Safe for use with acid-tolerant RO, NF, UF, and MF membranes within OEM-recommended pH ranges.
- Extended Membrane Life – Prevents irreversible fouling, minimizing the need for premature membrane replacement.
- Operational Efficiency – Restores normalized flow and reduces pressure drop, improving overall system productivity.
- Versatile Use – Effective in industrial, municipal, food & beverage, and desalination applications.
- Environmentally Safer Option – Non-flammable formulation, easy to handle and store compared to stronger mineral acids.
Frequently Asked Questions FAQs on Membrane Cleaning Liquid
- Normalized permeate flow drops by 10–15%, or
- Differential pressure rises by 15–20%.

| Product Name | RXSOL-33-1092-025 |
| Product Type | ORG 75 Membrane Clean MC Acid Cleaner |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Points: Mumbai, Kandla, Kolkata, Vizag, Chennai, Fujairah UAE, Muscat Oman, Kenya
| Phone | +91 22 65113333 / 5555 / 9999 / 27611360 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| mail@rxmarine.com |

| Name | CAS # | % by Weight |
|---|---|---|
| Proprietory Blend of non-hazardous acidic agents, buffers, chelating Agents and corrosion Inhibitors | N/A | > 30 |

|
Odour |
Odourless. |
|
Appearance |
Liquid, pale yellow, soluble in water. |
|
Contact with eyes |
Can cause damage to the eyes. |
|
Contact with skin |
Causes burns (R34). |
|
Inhalation |
Vapours or aerosols may cause irritation of eyes, nose and respiratory tract, Can cause damage to the lungs. |
|
Ingestion |
The ingestion of significant quantities may cause damage to digestive syste. |

|
Inhalation |
After inhalation medical attention require |
|
Skin Contact |
In case of contact with skin , wash immediately with plenty of water and soap. Remove contaminated clothes. |
|
Eye Contact |
Flush with running water for at least 15 minutes Immediately medical attention require. |
|
Ingestion |
seek medical attention , try to drink more plenty of fresh water. |

|
Suitable |
Not known , on direct exposure to heat dangrous emission of gas of COx SOx can be released |
|
Not suitable |
Not applicable |
|
Special |
Not applicabe |
|
Protection of fire Fighter |
Not applicable |
|
Precaution for fire-fighters |
Wear protective equipment with breathing apparatus. |

|
Enviromental Precaution |
Direct flow into drainage system, surface or ground water is prohibited. First of all neutralize with alkaline materials like lime powder for pH balancing between 6-10. |
|
Cleaning Method |
Flush Spill Area with Water and avoid contact with skin and eye. |

|
Condition to Avoid |
Non flammable but avoid direct heating |
|
Materials to Avoid |
Do not subject to ALKALINE medium. |
|
Handling |
Keep Container Tightly Closed |
|
NOTE |
Eyewash facilities require at workplace |
|
The product causes corrosion on skin and mucous membranes Pl. Note that In case of discharge of acidic or alkaline products into the sewerage system the pH must be in the range of 6-10 since higher or lower pH values may damage the sewerage system or impair biological dosage treatment plants. So that for maintaining pH we have to add acidic / basic medium neutaliser . For example if pH is less than 6 basic neutraliser is required and if pH is more than 10 acidic nature neutraliser is required. For details of any guideline pl. Visit our technical website www.rxmarine.com |
|
NOTE: On Use, the product is diluted - Wash hands thoroughly after handling. In case of mechanical failure or when dealing with an unknown product dilution, wear full Personal Protective Equipment (PPE).

|
Personal protection: |
|
|
Respiratory System Protection |
Approved respirator must be worn when spraying |
|
Eye Protection |
Strictly wear eye protection |
|
Hand protection |
wear PVC chemical resistance protective gloves |
NOTE: On Use, the product is diluted - Adequate general ventilation is typically sufficient to control exposure to contaminants.

|
Appearance |
Clear liquid |
|
Density |
g/cm3 at 15°C: > 1.1 |
|
pH |
10% solution 1.5-2.5 |
|
Flash Point |
Not applicable |
|
Compatibility |
|
|
Metal |
Concentrate and long touch may corrode. |
|
Rubber |
No known effect |

|
Hazardous Decomposition Products |
Do not occur if stored and used as directed. In FIRE combustion CO, CO2 , NH3 , SOX etc hazardous gas produced. |
|
NOTE |
AVOID CONTACT WITH ALKALINE SUBJECT. |

|
Skin Irritation |
Cause severe irritation |
|
Eye Irritat |
Cause severe irritation |
|
Sensitization |
Cause Sensitizing |
|
Chronic Toxicity |
Not Identified |
|
Carcinogencity |
No. |
NOTE: On Use, the product is diluted

RXSOL MB 1011 is degradable , and due to highly acidic in nature must be neutralized as per guidance and ingridents used in it.Direct contact is Harmful to aquatic organism.

As per guide line of local rules and regulation and before disposal and neutralization pl. refer 07 article.

|
Transport over land ADR/RID |
1805 8/11c 8/11c |
|
Transport over inland waterways ADN/ADNR |
|
|
Transport over sea IMDG |
8 |
|
Transport by air ICAO/IATA |
8/1805 |
|
Phosphoric acid |
|
|
sea |
EMS 8-08, MFAG 700 PG III |

|
Classification and labelling according to 4. Novelle Gefahrstoff-Verordnung |
|
|
Symbols of danger |
C Corrosive |
|
R-phrases |
R34 : Cause burns |
|
S-phrases |
S26 : In case of contact with eyes, rinse immediately with plenty of water and seek medical. advice. S45 : In case of accident or if you feel unwell, seek medical advice immediately |
|
National prescriptions |
|
|
Water hazard class (WGK) |
2 (self classification on the basis of component assessments or analogy conclusions without addition/subtraction of points for good/poor biodegradability etc.) |

| This information is based on our current level of knowledge and relates to the product in the state in which it is delivered. It is intended to describe our products from the point of view of safety requirements and is not intended to guarantee any particular properties. |
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.