Hardness Control Liquid

Liquid product used for the reduction of hardness in boilers. Hardness Control is highly soluble in water and It will precipitate calcium hardness as a non-adherent sludge.

Hardness Control is a Liquid product used for the reduction of hardness in boilers and to adjust hardness and phosphate. Hardness Control is highly soluble in water and It will precipitate calcium hardness as a non-adherent sludge.

USEFULL  to adjust hardness and phosphate .

A precipitant designed to elimate scale deposits and lower the hardness of water in boilers with working pressure up to 60 bars.

It is used in conjunction with alkaline liquid to prevent calcium scale deposits. Both products are used in our standard boiler water treatment programs for low-pressure boiler systems (0-32 bar) and medium-pressure steam propulsion vessels (32-60 bar).  Reduction of Hardness in boiler water system, and convert these salts in non adherent to avoid scale formation. It will precipitate calcium hardness chemically.

Application

Hardness Control is formulated to form a precipitate with calcium ions which will not adhere to metal surfaces but are in a form suitable for blowdown.


 

Dose

For optimum results dose Hardness Control direct to the boiler via the bypass pot-feeder. The dry powder should be dissolved in hot water (50°C) at a ratio of 1 part powder to twenty parts condensate (e.g. 500 grams/10 litres). Ensure that treatment is fully dissolved before dosing.

Dosage and control

 

 

Phophate test result in pPM PO4

 

 Pressure

 0 - 10

10 - 20

20 - 30

30 - 40

40 - 50

> 50

 Control range

 0-40 Bar
0-588 PSI

 23

11.5 

Satisfactory

Satisfactory

Blow Down

 20-50

41-60 Bar
589-880 PSI 

 17

 5.5

Satisfactory

Blow Down

Blow Down

  15-30

 > 60 Bar
> 880 PSI

 5.5

 Satisfactory

Satisfactory

Blow Down

Blow Down

 10-25

Select row on righthand side for applicable pressure range. Compare test result with comment in table and dose stated amount of product per ton boiler water volume.

These are recommended values based on experience and are in no way intended to replace the boiler manufacturer's specifications or company regulations.

RXSOL Boiler Corrosion Scale Treatment should be fed continuously in order to properly protect the boiler. Boiler Corrosion Scale Treatment can be fed neat or in any convenient dilution made up in soft water or cooled condensate. Boiler Corrosion Scale Treatment should be dosed using individual chemical dosing unit, must not be mixed with oxygen scavengers or condensate system corrosion inhibitors in concentrated form (e.g. concentrated chemical products should not be mixed together).

Sampling and Testing
Boiler Corrosion Scale Treatment is normally used in conjunction with RXSOL Alkalinity Control treatment in a conventional alkaline phosphate treatment programme for HP boilers, where independent control of phosphate and alkalinity control is required.

Dosing and Control
The dosage of Boiler Corrosion Scale Treatment depends on a number of operational factors such as feed-water quality, boiler design and steam rate. Control of Boiler Corrosion Scale Treatment is by a simple test to give the required level of phosphate (as PO4) in the boiler water. A simple Hardness Treatment test kit is available for this purpose. NOTE: Dependent on water quality, Boiler Corrosion Scale Treatment dosed at 0.25 liters/ton will increase the phosphate reserve by the order of 10mg/l.

Technical specifications

Sampling And Testing

A sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Follow the Rxsol Hardness Test Kit instructions and fill the Boiler Water Log Form according to result results. It is important that regular testing is carried out to ensure levels of treatment are correct.

Physical Properties :

Appearance        :MILKY LIQ
Corrosive action  : non
pH 1% solution   : 8,8
Flash point         : none

Note

Benefit and Features

  • Highly active phosphate based compound, economical in use.
  • Easily dissolved in water for dosing.
  • Scale problems due to calcium are eliminated.
  • Maintains sludge in a non-adherent state for ease of blow down.
  • Simple test to determine level of treatment.
  • Can be used for boilers of all pressures.
    Rxsol Hardness Control does not influence the alkalinity in the system
Remarks / Precaution

Why Choose RXSOL Hardness Control Corrosion Scale Inhibitor for Boiler?

Choosing RXSOL Hardness Control Corrosion Scale Inhibitor for Boiler means opting for reliable scale prevention that keeps your boiler systems free from scale build-up, ensuring they maintain efficiency and performance. Its comprehensive corrosion protection, featuring an iron/tannate film and oxygen removal, provides robust protection for your entire system. The low toxicity formulation ensures safe handling while delivering effective results.

Industry professionals prefer RXSOL Hardness Control Corrosion Scale Inhibitor for its proven effectiveness in protecting critical infrastructure, making it a trusted choice in the field.

Features

Liquid Product: Easy application for convenience.

Benefits

Enhanced Protection: Safeguards feed tank, feed lines, and boiler metal from corrosion and scale. Maintains Water Quality: Does not add to boiler Total Dissolved Solids (TDS).

Packing sizes
Boiler water hardness resulting tuff scale in side the system tubes, which becomes very tuff to remove. So its prior treatment with HARDNESS control is wise decision. We are keeping ready stock of material in 25, 50 Ltr packing.
MSDS

Product Name : RXSOL-50-5021-025
Product Type : HARDNESS CONTROL LIQUID

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point : Mumbai, Kandla, Kolkata, Chennai, Vizag, Surat, Fujairah, Muscat, Nairobi

Phone : +91 22 65113333 / 5555 / 9999 / 27611360
Fax : +91 22 2781 1318 :::AOH :0091 9821214367
Email : mail@rxmarine.com

Chemica Name

Concentration

CAS Number

EC Number

Sodium Hexa Meta Phosphate

80-90

10124-56-8

233-343-1

Proprietory Blend of POLYMER 10-20 ........... .......

*See Section 16

Odour

Odourless.

Appearance

Clear, soluble in water.

Contact with eyes

Prolonged exposure may cause abrasive irritation of the eyes.

Contact with skin

In cases of severe exposure, irritation may develop.

Inhalation

Prolonged exposure may cause abrasive irritation of the mucous membranes.

Ingestion

The ingestion of significant quantities may cause gastro-intestinal disturbances.

Contact with skin

Wash affected area with plenty of soap and water

Contact with eyes

If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes Irrigate eyes thoroughly whilst lifting eyelids.When in doubt or symptoms persist, seek medical attention

Ingestion

Never give anything by mouth to an unconscious person.Give water or milk to drink.When in doubt or symptoms persist, seek medical attention

Inhalation

Remove patient to fresh air.Seek medical attention if irritation persists

General

In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45)

- Non-combustible solid
- Decomposition products may include phosphorous compounds
- Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions

Personal Precautions

Wear protective clothing as per section 8.Avoid raising dust.

Environmental Precautions

No special precautions are required for this product.

Clean Up Actions

Sweep or shovel-up spillage and remove to a safe place.Wash spill site with water and detergent.

Special Precautions

Wear protective clothing as per section 8.

Handling

The usual precautions for handling chemicals should be observed.

Storage

Keep only in the original container in a cool, well ventilated place (S3/9/49).

Exposure Limits

There are no recommended or established controls for this product.

Occupational exposure controls

Wear suitable dust mask e.g. to BS 2091.Wear suitable protective clothing, including eye/face protection and gloves (plastic or rubber are recommended).

gloves                   goggles                   suit                    no_smoking

Gloves                      Goggles                         Suit                        No_Smoking

Odour

Odourless

Appearance

Clear Liquid, soluble in water

pH

6 at 1 % concentration

Vapour pressure

not known

Melting point

>600 °C at 760 mm /Hg - Water solubility ~100 g/l

Density

1100 kg/m3

Non-combustible solid

 

- This article is considered stable under normal conditions+9
- Avoid contact with moist air
- See Section 5

Toxicological information

LD50 (dermal) : 7250 mg/kg

Inhalation

May cause irritation

Contact with skin

In cases of severe exposure, redness and irritation may develop

Contact with eyes

May cause irritation

Ingestion

No effects for small dosage. Large dose effects not known
The ingestion of significant quantities may cause gastro-intestinal disturbances

Carcinogenicity

No evidence of carcinogenic effects

Ecotoxicity

No hazard to the aquatic environment

Mobility

Completely soluble in water

Persistence and Biodegradability

Degrades by hydrolysis

Bioaccumulation Potential

Bioaccumulation is insignificant

Other Adverse Effects

No environmental problems are expected when the product is used / handled correctly. In its   intended use, the product will not be released into the environment.Presents little or no hazard to the environment.

Classification

EU Waste class

Disposal considerations

Follow waste treatment method Do not discharge directly into drains or the environment. dispose to an authorised waste collection point Disposal should be in accordance with local, state or national legislation

- Not classified as hazardous for transport

Risk Phrases

Not applicable

Safety Phrases

Not applicable

The information provided about the product on this Safety Data Sheet has been compiled from knowledge of The individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product In terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). This Safety Data Sheet is provided in compliance with The Directive (67/548/EEC) This Safety Data Sheet is provided in compliance with The Preparations Directive (88/379/EEC) This Safety Data Sheet is provided in compliance with The Safety Data Sheets Directive (2001/58EC)

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Need a quote for this product?

Tell us the grade, packing and quantity you need — we ship across India and to major ports.

Request a quote office@mumbaichemical.com