Sea Water Scale Dissolver

Sea Water Scale Remover Cleaner Sea Water SIDE is specialized product to dissolve water scale smoothly.

Air Cooler Scale Remover Cleaner Sea Water SIDE is specialized product to dissolve water scale smoothely. We are manufacturer and supplier of Air Cooler Cleaner Sea Water SIDE.

Application

RXSOL-54-1048-020  is mixed with fresh water 3 to 20 percent depending on deposition of scaling.

If the equipment to be cleaned is contaminated by oil, grease, sludge or carbonized oil, then first of all clean the system with degreaser  RXSOL-10-1005. RXSOL-54-1048-020 should be mixed with fresh water to form a solution of 10-30%, depending on the extent of scaling. After using RXSOL-54-1048-020 ,  

PRECAUTION :::it is essential to thoroughly rinse all metal surfaces at least once with a 0.5% solution of  RXSO-20-2005  in fresh water. This solution should be circulated for 2-4 hours or until an acceptable pH value is obtained. This will neutralize any remaining acidity & passivate steel surfaces.

Dose

After using  RXSOL-54-1048-020, sense all metal surfaces with 0.5 percent of  RXSOL-10-1005, at least 2-4 hour , up to neutral of PH value.

• Fast and effective scale remover.
• Soft on ferrous metals.
• Removes water scale & rust from boilers/diesel engine & other cooling system
• As well as from condensers, evaporators, & heat exchangers etc
 

Why Use RXSOL Descaler?

  • It is a safe , economical concentrated  chemical to be used on the waterside of heat transfer equipment.
  • You do not have to heat RXSOL-54-1048-020 .
    RXSOL-54-1048-020  is safer for the employees to use than other acid products.
  • Your equipment will be cleaned in only hours without disassembling any part of the equipment. Equipment can also be cleaned without any down time (cleaning on the run).
  •  Cleans down to the original surface without pitting.
  •  RXSOL-54-1048-020 is safe on copper, copper-nickel, bronze, brass, iron, stainless steel and rubber.
  •  RXSOL-54-1048-020  will extend the usable life of your equipment, especially when used as a part of a regularly scheduled preventative maintenance program.
  •  Removing the scale build up allows your equipment to operate more efficiently with less down time.

     
Technical specifications

Procedure-of-use: The most effective descaling is accomplished by circulation.In the case of small components,the soak method in an immersion bath can be used. If the equipment to be cleaned is contaminated by oil, grease or sludge, then pre-cleaning with DEGREASER ( RXSOL OB 1005 ) is necessary. Depending on the extent of scaling, use a solution of 2.5-10% RXSOL-54-1008-025 . The solution will have a red colour which changes to orange when 85% of the acid has been neutralized , & to colourless  when the solution is totally neutralized. Whenever possible, the solution should be heated to 60°C.Neutralised  solutions can be re-activated by adding more RXSOL-54-1008-025  until the red colour reappears. 

Fields: Descaling of  Boilers, Descaling  of Diesel Engine Cooling Systems, Condenser, Pipeline collection system, Evaporators, Calorifiers, Heat Exchangers,The strength of the acid can be enhanced by adding 1part sodium chloride (common salt) to 20 parts of Descalex.If salt is not available, an acceptable alternative is to dissolve RXSOL-54-1008-025  in sea water. After use of RXSOL-54-1008-025  a  0.5% solution of Alkalinity Control in fresh  water should be used for neutralization.

Note

 

Automotive - Closed Circuit Cooling, Dynamometers, Extruders, Molders, Radiators, Welders

Bottling - CO2 Generators, Heaters, Exchangers, Rinse Tanks, Sterilizers, Washers

. HOUSE HOLD - Dissolves hard and old lime scale deposits from your appliances. It extends the life of the appliance and saves running cost. It can be used in appliances such as Washing Machines, Dish Washers, Geysers, Steam Iron, Coffee Makers, Bath Tubs, Bathroom Fixtures etc.

Buildings - Chillers, Cooling Towers, Pipework

Chemicals - Dryers, Extruders, Kettles, Mixers, Reactors, Scrubbers, Vacuum Pumps

Food - Condensers, Ice Machines, Kathabars, Refrigeration Equipment, Steam Tables

Manufacturing - Chillers, Compressors, Furnaces, Quenchers, Vacuum Pumps

Metals - Bearings, Castings, Fans, Hearth & Vacuum Furnaces, Shelters, Sprays

Mining - Bearings, Conveyors, Filters, Presses, Process Lines, Radiators

Paper- Calendar Mill Rolls, Caustic Lines, Scrubbers, Compressors, Liquor Tanks, Pulverizers, Vacuum Pumps

Pharmaceutical- Exchangers, Loop Systems, Kathabars, Pumps, Reactors, Stills, Sterilizers

Refinery - Compressors, Converters, Crackers, Exchangers, Piping, Pumps

Rubber/Plastics - Banbury Mixers, Calendar & Mill Rolls, Extruders, Injection Molders, Molds, Temperature Control Units, Throat Coolers, Towers, Tubers

Steel - Bearings, ConCast Units, Generators, Hearths, Spangle Units, Furnaces

Textile - Air Washers,Compressors, Condensers, Exchangers, Extruders,Towers

 

Boilers

Condensers

Filters

Heat Exchangers

Kettles & Tanks

Pipelines

Pots

Reactors

Steam Jackets

Bath Rooms and Showers

Metal Processing and much more!


 

Applications


  Automotive

  Bottling

  Chemicals

  Food

  - Closed Circuit Cooling

  - Dynamometers

  - Extruders

  - Molders

  - Radiators

  - Welders

  - CO2 Generators

  - Heaters

  - Exchangers

  - Rinse Tanks

  - Sterilizers and Washers

  - Dryers

  - Extruders

  - Kettles

  - Mixers

  - Reactors

  - Scrubbers

  - Vacuum Pumps

  - Condensers

  - Ice Machines

  - Kathabars

  - Refrigeration Equipment

  - Steam Tables

  Manufacturing

  Metals

  Mining

  Paper

  - Chillers

  - Compressors

  - Furnaces

  - Quenchers

  - Vacuum Pumps

  - Bearings

  - Conveyors

  - Fans

  - Hearth & Vacuum Furnaces

  - Shelters

  - Sprays

  - Bearings

  - Conveyors

  - Filters

  - Presses

  - Process Lines

  - Radiators

  - Calendar Rolls

  - Mill Rolls

  - Caustic Lines

  - Scrubbers

  - Compressors

  - Liquor Tanks

  - Pulverizers

  - Vacuum Pumps

  Pharmaceutical

  Refinery

  Rubber & Plastics

  Steel

  - Exchangers

  - Loop Systems

  - Kathabars

  - Pumps

  - Reactors

  - Stills

  - Sterilizers

  - Compressors

  - Converters

  - Crackers

  - Exchangers

  - Piping

  - Pumps

  - Banbury Mixers

  - Calendar & Mill Rolls

  - Extruders

  - Injection Molders

  - Molds

  - Temperature Control - Units

  - Throat Coolers

  - Towers and Tubers

  Bearings

  ConCast Units

  Generators

  Hearths

  Spangle Units

  Furnaces

  Textile

  Utilities

  Other Applications

   

  - Air Washers

  - Compressors

  - Condensers

  - Exchangers

  - Extruders and Towers

  - Boilers

  - Turbines

  - Transformers

  - Cooling Towers

  - Air Compressors

  - Hydrogen Coolers

  - Lube Oil Heat Exchangers

  - Ball Mills

  - Demisters

  - Evaporators

  - Locomotives

  - Absorption Units

  - Diesel Generators

  - Induction Furnaces

 
 

Remarks / Precaution

RXSOL-54-1048-020 should not be used on Aluminium, Zinc, Tin, or any Galvanized Surfaces for which a special grade cleaner should be used. Chemical Cleaning Module RX cleansers has developed a 280 litres capacity cleaning module, primarily designed for use with chemical acid solvents for descaling boilers, calorifiers, heat exchangers & other types of equipment where rust & scale form RXSOL-11-1008--DC Boilers, See RX cleansers Practical Application Manual

 

The engine room is the heart of any vessel, responsible for the propulsion and essential power systems that keep the ship running smoothly. Proper engine room maintenance is critical to ensuring safety, efficiency, and regulatory compliance. At RXMARINE International, we specialize in providing high-quality marine chemicals that enhance maintenance procedures, keeping vessels in top condition.

Why Engine Room Maintenance Matters

  • Prevents Downtime & Costly Repairs: Regular inspections help detect early signs of wear and tear, reducing expensive breakdowns.

  • Enhances Fuel Efficiency: A well-maintained engine operates efficiently, cutting down fuel consumption and operational costs.

  • Ensures Crew Safety: Proper maintenance minimizes the risk of hazardous incidents such as fires, leaks, or mechanical failures.

  • Regulatory Compliance: Compliance with international maritime regulations (IMO, SOLAS) is essential to avoid fines and ensure smooth sailing.

Key Aspects of Engine Room Maintenance

1. Cleaning & Degreasing

The accumulation of oil, grease, and dirt can lead to overheating and reduced efficiency. Using RXMARINE’s Engine Room Cleaners & Degreasers, you can effectively remove sludge, carbon deposits, and oil residues.

2. Lubrication System Maintenance

  • Regular oil changes using high-quality marine lubricants help prevent friction and wear.

  • Monitoring oil viscosity and contamination is crucial to detect potential engine issues early.

3. Cooling System Efficiency

  • Scale and corrosion in heat exchangers and cooling lines reduce efficiency. Descaling chemicals like RXMARINE’s RXSCALE help prevent blockages and maintain optimal cooling.

  • Ensure coolant levels are checked regularly to prevent overheating.

4. Fuel System Treatment

  • Fuel contamination with water, sludge, and microbial growth can affect engine performance. Using fuel additives and biocides prevents clogging and improves combustion efficiency.

  • Regularly clean fuel injectors and filters to maintain smooth operation.

5. Bilge Cleaning & Oil Spill Management

  • The bilge area accumulates oil and sludge, which can pose environmental and safety hazards.

  • RXMARINE’s Oil Spill Dispersants & Bilge Cleaners effectively break down oil and prevent pollution.

6. Corrosion Prevention

  • Saltwater exposure accelerates corrosion in pipes, tanks, and metal surfaces.

  • Apply corrosion inhibitors and protective coatings to extend the life of engine room components.

Best Practices for Engine Room Maintenance

  • Implement a Routine Inspection Schedule – Daily, weekly, and monthly checks help identify problems early.
  • Train Crew Members – Ensure engineers and crew are well-trained in maintenance procedures.
  • Use High-Quality Marine Chemicals – Investing in premium cleaning, degreasing, and protective products ensures longevity and efficiency.
  • Document Maintenance Activities – Keeping detailed logs helps in audits, repairs, and regulatory compliance.
Packing sizes
Air Cooler Scale Dissolver Air Cooler Chemical Sea Water SIDE Scale Dissolver from AIR COOLER water side available in 4 Ltr, 25 Ltr Packing.
MSDS

Product Name

Sea Water Scale Dissolver RXSOL-25-1048-020

Product Type SCALE CLEANER

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point :  Mumbai, Kandla, Kolkata, Chennai, Vizag, Gandhidham, Fujairah, Muscat

Phone +91 22 65113333 / 5555 / 9999
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email 123@rxmarine.com
Website www.rxmarine.com

Chemical Name

Concentration

CAS Number

EC Number

R Phrases*

Symbols

Ethanoic Acid  (Acetic Acid)

20-40

64-19-07

 200-580-7    

35, 10

C

Corrosion Inhibitor

 2-5

NA 

 NA

NA 

 

Formic Acid 10-18        

Polymeric Combination      35-40

Oxalo compound                6-8% for extra cleaning of scale and rust prevntion
Citric Acid                           5-7%
*See Section 16

corrosive

Corrosive

Odour

Strong pungent smell 

Appearance

Liquid, pale yellow, soluble in water

Contact with eyes

Can cause damage to the eyes

Contact with skin

Prolonged skin or eye contact may cause chemical burns

Inhalation

Causes  severe  irritation,  May  cause  breathing  difficulty

Ingestion

Not regarded as a potential route of exposure.,Causes burning sensation  

 

Contact with skin

Remove contaminated clothing immediately and drench affected skin with plenty of water. Then wash with soap and water When in doubt or symptoms persist, seek medical attention. Contaminated clothing should be laundered before reuse 

Contact with eyes
 

If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes. Irrigate eyes thoroughly whilst lifting eyelids Seek. immediate medical attention. Continue flushing with water until medical help arrives. 

Ingestion

Never make an unconscious person vomit or drink fluids Give plenty of water to drink Do not induce vomiting Seek immediate medical attention 

Inhalation

Remove patient to fresh air Keep warm and at rest, in a half upright position. Loosen clothing. When in doubt or symptoms persist, seek medical attention.

General

In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45).

-  Non combustible.
-  Smoke from fires is corrosive, Hydrogen chloride may be formed.
-  Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions.
-  Substance evolves toxic fumes, wear self-contained breathing apparatus.
-  Use water spray or fog to knock down and absorb corrosive fumes.

Personal Precautions

Wear protective clothing as per section 8 Vapours are heavier than air and may travel considerable distances to a source of ignition and flashback. 

Environmental Precautions

Do not allow to enter public sewers and watercourses.

Immediate Actions

Use appropriate containment to avoid environmental contamination (S57).

Clean Up Actions

Absorb spillage in inert material and shovel up Ventilate the area and wash spill site after material pick-up is complete. 

Special Precautions

Wear protective clothing as per section 8 Avoid release to the environment. Refer to special instructions/Safety data sheets (S61) Vapours are heavier than air and may travel considerable distances to a source of ignition and flashback.

Handling

Avoid contact with skin and eyes (S24/25).Do not breathe vapour/fumes (S23).Eyewash bottles should be available.Wear protective clothing as per section 8.Ensure adequate ventilation.In use, may form flammable/explosive vapour-air mixture (R18).

Storage

Keep only in the original container in a cool, well ventilated place (S3/9/49). Keep in acid store.

Exposure Limits

TLV (TWA) 20 ppm, 122 mg/m3 (1,2-Dichlorobenzene).

Exposure controls

The undiluted product must not be used in a confined space without good ventilation.

Occupational exposure  controls

Wear approved respirator if exposure likely to exceed MEL/OES  Wear goggles giving complete eye protection Wear suitable protective clothing, including eye/face protection and gloves (neoprene or nitrile  are recommended).

gloves                suit                visor

Gloves                       Suit                          Visor

Odour

Strong smell 

Appearance

Liquid, pale yellow, soluble in water

PH

1.5 at 100 % concentration

Boiling point

~ 100 °C at 760 mm /Hg

Vapour pressure

105.5 at 20 deg C

Vapour density (air = 1)

1.26

Freezing point~

30 °C at 760 mm/Hg

Completely soluble in water

Specific gravity (water=1)

1.16

Non combustible 

-  This article is considered stable under normal conditions, May cause rubber to swell
-  Avoid overheating
-  Incompatible with strong oxidizing substances, Contact with alkaline earth metals may form explosive gases, Contact with alkali metals may form explosive gases
-  See Section 5

Contact with skin

In cases of severe exposure, redness and irritation may develop 

Contact with eyes

Causes irritation

Ingestion

May cause gastro-intestinal disturbances

Carcinogenicity

No evidence of carcinogenic effects

Ecotoxicity

This product does not contain ingredients which are classified in the EU as dangerous for theenvironment. 

Mobility

Completely soluble in water .

Persistence and Biodegradability

Its main ingredients will either dissolve rapidly and dissociate in water or are readily/inherently  biodegradable.

Bioaccumulation Potential

Bioaccumulation of the components in this product is insignificant. Other Adverse Effects No environmental problems are expected when the product is used / handled correctly. 

Classification 
 

This material and/or its container must be disposed of as hazardous waste EU Waste class Disposal considerations Do not discharge into drains or the environment, dispose to anauthorised waste collection point Disposal should be in accordance with local, state or national legislation.

Proper Shipping Name:
UN        
  Proper Shipping Name: Ethanoic Acid solution    
  UN NO.

2789

   
  Hazard Class 8 PackingGroup II

Road/Rail(ADR/RID)

  Proper Shipping Name

Ethanoic Acid  solution

   
  ADR UN No.

2789

   
 

ADRHazardClass

8 Tremcard

80GC1789-II

Sear (IMDG)
  Proper Shipping Name

Ethanoic Acid 

   
  IMDG UN No.

2789

   
  IMDG Hazard Class 8 IMDG PackGroup.:

II

  IMDG EmS F-A, S-B IMDG subrisk

N/A

 

IMDG Labels

8

IMDG Flashpoint:

 N/A

Air(ICAO/IATA)

  ProperShippingName

Ethanoic Acid 

   
  IMDG UNNo

2789

   
  IMDG HazardClass 8 ICAO PackingGroup

II

  ICAO subrisk N/A ICAO Labels:

8+CAO

  ICAO Flashpoint

N/A

   

DOT/ CFR(USDepartment ofTransportation

 

DOTProperShippingName

Ethanoic Acid 

   
 

HazardousMaterial

Ethanoic Acid 

   
  HazardClass 8 IdentificationNumber: UN2789
 

Product RQ (lbs)

N/E DOTsubrisk:

N/A

 

DOTLabels

8

DOTFlashpoint: N/A

- Not classified as hazardous for transport

Risk Phrases

Irritating to eyes (R35 - R10) 

Safety Phrases Irritant

In case of contact with eyes, rinse immediately with plenty of water and seek medical advice (S26)Wear suitable gloves and eye/face protection (S45) 

Text of R and S phrase codes used in this safety data sheet:-
R34 Causes burns;
R36 Irritating to eyes;
R37 Irritating to respiratory system;
R41 Risk of serious damage to eyes.
The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). The product is not sold as suitable for other applications - usage in such may cause risks not mentioned in this sheet. Do not use for other appli-cation(s) without seeking advice from manufacturer This Safety Data Sheet is provided in compliance with The Dangerous Substances Directive (67/548/EEC) This Safety Data Sheet is provided in compliance with The Dangerous Preparations Directive (88/379/EEC) This Safety Data Sheet is provided in compliance with The Safety Data Sheets Directive (2001/58EC) Composition information in accordance with Regulation (EC) No 648 /2004 of the European Parliament and of the Council of 31 March 2004 on detergents: Nonionic surfactants 5-15 % Amphoteric surfactants 5 %

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Need a quote for this product?

Tell us the grade, packing and quantity you need — we ship across India and to major ports.

Request a quote office@mumbaichemical.com