Air Cooler Scale Remover Cleaner Sea Water SIDE is specialized product to dissolve water scale smoothely. We are manufacturer and supplier of Air Cooler Cleaner Sea Water SIDE.
RXSOL-54-1048-020 is mixed with fresh water 3 to 20 percent depending on deposition of scaling.
If the equipment to be cleaned is contaminated by oil, grease, sludge or carbonized oil, then first of all clean the system with degreaser RXSOL-10-1005. RXSOL-54-1048-020 should be mixed with fresh water to form a solution of 10-30%, depending on the extent of scaling. After using RXSOL-54-1048-020 ,
PRECAUTION :::it is essential to thoroughly rinse all metal surfaces at least once with a 0.5% solution of RXSO-20-2005 in fresh water. This solution should be circulated for 2-4 hours or until an acceptable pH value is obtained. This will neutralize any remaining acidity & passivate steel surfaces.
After using RXSOL-54-1048-020, sense all metal surfaces with 0.5 percent of RXSOL-10-1005, at least 2-4 hour , up to neutral of PH value.
• Fast and effective scale remover.
• Soft on ferrous metals.
• Removes water scale & rust from boilers/diesel engine & other cooling system
• As well as from condensers, evaporators, & heat exchangers etc
Why Use RXSOL Descaler?
- It is a safe , economical concentrated chemical to be used on the waterside of heat transfer equipment.
-
You do not have to heat RXSOL-54-1048-020 .
RXSOL-54-1048-020 is safer for the employees to use than other acid products. -
Your equipment will be cleaned in only hours without disassembling any part of the equipment. Equipment can also be cleaned without any down time (cleaning on the run).
- Cleans down to the original surface without pitting.
- RXSOL-54-1048-020 is safe on copper, copper-nickel, bronze, brass, iron, stainless steel and rubber.
- RXSOL-54-1048-020 will extend the usable life of your equipment, especially when used as a part of a regularly scheduled preventative maintenance program.
-
Removing the scale build up allows your equipment to operate more efficiently with less down time.
Procedure-of-use: The most effective descaling is accomplished by circulation.In the case of small components,the soak method in an immersion bath can be used. If the equipment to be cleaned is contaminated by oil, grease or sludge, then pre-cleaning with DEGREASER ( RXSOL OB 1005 ) is necessary. Depending on the extent of scaling, use a solution of 2.5-10% RXSOL-54-1008-025 . The solution will have a red colour which changes to orange when 85% of the acid has been neutralized , & to colourless when the solution is totally neutralized. Whenever possible, the solution should be heated to 60°C.Neutralised solutions can be re-activated by adding more RXSOL-54-1008-025 until the red colour reappears.
Fields: Descaling of Boilers, Descaling of Diesel Engine Cooling Systems, Condenser, Pipeline collection system, Evaporators, Calorifiers, Heat Exchangers,The strength of the acid can be enhanced by adding 1part sodium chloride (common salt) to 20 parts of Descalex.If salt is not available, an acceptable alternative is to dissolve RXSOL-54-1008-025 in sea water. After use of RXSOL-54-1008-025 a 0.5% solution of Alkalinity Control in fresh water should be used for neutralization.
• Automotive - Closed Circuit Cooling, Dynamometers, Extruders, Molders, Radiators, Welders
• Bottling - CO2 Generators, Heaters, Exchangers, Rinse Tanks, Sterilizers, Washers
. HOUSE HOLD - Dissolves hard and old lime scale deposits from your appliances. It extends the life of the appliance and saves running cost. It can be used in appliances such as Washing Machines, Dish Washers, Geysers, Steam Iron, Coffee Makers, Bath Tubs, Bathroom Fixtures etc.
• Buildings - Chillers, Cooling Towers, Pipework
• Chemicals - Dryers, Extruders, Kettles, Mixers, Reactors, Scrubbers, Vacuum Pumps
• Food - Condensers, Ice Machines, Kathabars, Refrigeration Equipment, Steam Tables
• Manufacturing - Chillers, Compressors, Furnaces, Quenchers, Vacuum Pumps
• Metals - Bearings, Castings, Fans, Hearth & Vacuum Furnaces, Shelters, Sprays
• Mining - Bearings, Conveyors, Filters, Presses, Process Lines, Radiators
• Paper- Calendar Mill Rolls, Caustic Lines, Scrubbers, Compressors, Liquor Tanks, Pulverizers, Vacuum Pumps
• Pharmaceutical- Exchangers, Loop Systems, Kathabars, Pumps, Reactors, Stills, Sterilizers
• Refinery - Compressors, Converters, Crackers, Exchangers, Piping, Pumps
• Rubber/Plastics - Banbury Mixers, Calendar & Mill Rolls, Extruders, Injection Molders, Molds, Temperature Control Units, Throat Coolers, Towers, Tubers
• Steel - Bearings, ConCast Units, Generators, Hearths, Spangle Units, Furnaces
• Textile - Air Washers,Compressors, Condensers, Exchangers, Extruders,Towers
Boilers
Condensers
Filters
Heat Exchangers
Kettles & Tanks
Pipelines
Pots
Reactors
Steam Jackets
Bath Rooms and Showers
Metal Processing and much more!
Applications
|
Automotive |
Bottling |
Chemicals |
Food |
|
- Closed Circuit Cooling - Dynamometers - Extruders - Molders - Radiators - Welders |
- CO2 Generators - Heaters - Exchangers - Rinse Tanks - Sterilizers and Washers |
- Dryers - Extruders - Kettles - Mixers - Reactors - Scrubbers - Vacuum Pumps |
- Condensers - Ice Machines - Kathabars - Refrigeration Equipment - Steam Tables |
|
Manufacturing |
Metals |
Mining |
Paper |
|
- Chillers - Compressors - Furnaces - Quenchers - Vacuum Pumps |
- Bearings - Conveyors - Fans - Hearth & Vacuum Furnaces - Shelters - Sprays |
- Bearings - Conveyors - Filters - Presses - Process Lines - Radiators |
- Calendar Rolls - Mill Rolls - Caustic Lines - Scrubbers - Compressors - Liquor Tanks - Pulverizers - Vacuum Pumps |
|
Pharmaceutical |
Refinery |
Rubber & Plastics |
Steel |
|
- Exchangers - Loop Systems - Kathabars - Pumps - Reactors - Stills - Sterilizers |
- Compressors - Converters - Crackers - Exchangers - Piping - Pumps |
- Banbury Mixers - Calendar & Mill Rolls - Extruders - Injection Molders - Molds - Temperature Control - Units - Throat Coolers - Towers and Tubers |
Bearings ConCast Units Generators Hearths Spangle Units Furnaces |
|
Textile |
Utilities |
Other Applications |
|
|
- Air Washers - Compressors - Condensers - Exchangers - Extruders and Towers |
- Boilers - Turbines - Transformers - Cooling Towers - Air Compressors - Hydrogen Coolers - Lube Oil Heat Exchangers |
- Ball Mills - Demisters - Evaporators - Locomotives - Absorption Units - Diesel Generators - Induction Furnaces |
RXSOL-54-1048-020 should not be used on Aluminium, Zinc, Tin, or any Galvanized Surfaces for which a special grade cleaner should be used. Chemical Cleaning Module RX cleansers has developed a 280 litres capacity cleaning module, primarily designed for use with chemical acid solvents for descaling boilers, calorifiers, heat exchangers & other types of equipment where rust & scale form RXSOL-11-1008--DC Boilers, See RX cleansers Practical Application Manual
The engine room is the heart of any vessel, responsible for the propulsion and essential power systems that keep the ship running smoothly. Proper engine room maintenance is critical to ensuring safety, efficiency, and regulatory compliance. At RXMARINE International, we specialize in providing high-quality marine chemicals that enhance maintenance procedures, keeping vessels in top condition.
Why Engine Room Maintenance Matters
-
Prevents Downtime & Costly Repairs: Regular inspections help detect early signs of wear and tear, reducing expensive breakdowns.
-
Enhances Fuel Efficiency: A well-maintained engine operates efficiently, cutting down fuel consumption and operational costs.
-
Ensures Crew Safety: Proper maintenance minimizes the risk of hazardous incidents such as fires, leaks, or mechanical failures.
-
Regulatory Compliance: Compliance with international maritime regulations (IMO, SOLAS) is essential to avoid fines and ensure smooth sailing.
Key Aspects of Engine Room Maintenance
1. Cleaning & Degreasing
The accumulation of oil, grease, and dirt can lead to overheating and reduced efficiency. Using RXMARINE’s Engine Room Cleaners & Degreasers, you can effectively remove sludge, carbon deposits, and oil residues.
2. Lubrication System Maintenance
-
Regular oil changes using high-quality marine lubricants help prevent friction and wear.
-
Monitoring oil viscosity and contamination is crucial to detect potential engine issues early.
3. Cooling System Efficiency
-
Scale and corrosion in heat exchangers and cooling lines reduce efficiency. Descaling chemicals like RXMARINE’s RXSCALE help prevent blockages and maintain optimal cooling.
-
Ensure coolant levels are checked regularly to prevent overheating.
4. Fuel System Treatment
-
Fuel contamination with water, sludge, and microbial growth can affect engine performance. Using fuel additives and biocides prevents clogging and improves combustion efficiency.
-
Regularly clean fuel injectors and filters to maintain smooth operation.
5. Bilge Cleaning & Oil Spill Management
-
The bilge area accumulates oil and sludge, which can pose environmental and safety hazards.
-
RXMARINE’s Oil Spill Dispersants & Bilge Cleaners effectively break down oil and prevent pollution.
6. Corrosion Prevention
-
Saltwater exposure accelerates corrosion in pipes, tanks, and metal surfaces.
-
Apply corrosion inhibitors and protective coatings to extend the life of engine room components.
Best Practices for Engine Room Maintenance
- Implement a Routine Inspection Schedule – Daily, weekly, and monthly checks help identify problems early.
- Train Crew Members – Ensure engineers and crew are well-trained in maintenance procedures.
- Use High-Quality Marine Chemicals – Investing in premium cleaning, degreasing, and protective products ensures longevity and efficiency.
- Document Maintenance Activities – Keeping detailed logs helps in audits, repairs, and regulatory compliance.

| Product Name |
Sea Water Scale Dissolver RXSOL-25-1048-020 |
| Product Type | SCALE CLEANER |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point : Mumbai, Kandla, Kolkata, Chennai, Vizag, Gandhidham, Fujairah, Muscat
| Phone | +91 22 65113333 / 5555 / 9999 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| 123@rxmarine.com | |
| Website | www.rxmarine.com |

|
Chemical Name |
Concentration |
CAS Number |
EC Number |
R Phrases* |
Symbols |
|
Ethanoic Acid (Acetic Acid) |
20-40 |
64-19-07 |
200-580-7 |
35, 10 |
C |
|
Corrosion Inhibitor |
2-5 |
NA |
NA |
NA |
|
| Formic Acid | 10-18 |
Polymeric Combination 35-40
Oxalo compound 6-8% for extra cleaning of scale and rust prevntion
Citric Acid 5-7%
*See Section 16

![]()
Corrosive
|
Odour |
Strong pungent smell |
|
Appearance |
Liquid, pale yellow, soluble in water |
|
Contact with eyes |
Can cause damage to the eyes |
|
Contact with skin |
Prolonged skin or eye contact may cause chemical burns |
|
Inhalation |
Causes severe irritation, May cause breathing difficulty |
|
Ingestion |
Not regarded as a potential route of exposure.,Causes burning sensation |

|
Contact with skin |
Remove contaminated clothing immediately and drench affected skin with plenty of water. Then wash with soap and water When in doubt or symptoms persist, seek medical attention. Contaminated clothing should be laundered before reuse |
|
Contact with eyes |
If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes. Irrigate eyes thoroughly whilst lifting eyelids Seek. immediate medical attention. Continue flushing with water until medical help arrives. |
|
Ingestion |
Never make an unconscious person vomit or drink fluids Give plenty of water to drink Do not induce vomiting Seek immediate medical attention |
|
Inhalation |
Remove patient to fresh air Keep warm and at rest, in a half upright position. Loosen clothing. When in doubt or symptoms persist, seek medical attention. |
|
General |
In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45). |

- Non combustible.
- Smoke from fires is corrosive, Hydrogen chloride may be formed.
- Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions.
- Substance evolves toxic fumes, wear self-contained breathing apparatus.
- Use water spray or fog to knock down and absorb corrosive fumes.

|
Personal Precautions |
Wear protective clothing as per section 8 Vapours are heavier than air and may travel considerable distances to a source of ignition and flashback. |
|
Environmental Precautions |
Do not allow to enter public sewers and watercourses. |
|
Immediate Actions |
Use appropriate containment to avoid environmental contamination (S57). |
|
Clean Up Actions |
Absorb spillage in inert material and shovel up Ventilate the area and wash spill site after material pick-up is complete. |
|
Special Precautions |
Wear protective clothing as per section 8 Avoid release to the environment. Refer to special instructions/Safety data sheets (S61) Vapours are heavier than air and may travel considerable distances to a source of ignition and flashback. |

|
Handling |
Avoid contact with skin and eyes (S24/25).Do not breathe vapour/fumes (S23).Eyewash bottles should be available.Wear protective clothing as per section 8.Ensure adequate ventilation.In use, may form flammable/explosive vapour-air mixture (R18). |
|
Storage |
Keep only in the original container in a cool, well ventilated place (S3/9/49). Keep in acid store. |

|
Exposure Limits |
TLV (TWA) 20 ppm, 122 mg/m3 (1,2-Dichlorobenzene). |
|
Exposure controls |
The undiluted product must not be used in a confined space without good ventilation. |
|
Occupational exposure controls |
Wear approved respirator if exposure likely to exceed MEL/OES Wear goggles giving complete eye protection Wear suitable protective clothing, including eye/face protection and gloves (neoprene or nitrile are recommended). |
![]()
Gloves Suit Visor

|
Odour |
Strong smell |
|
Appearance |
Liquid, pale yellow, soluble in water |
|
PH |
1.5 at 100 % concentration |
|
Boiling point |
~ 100 °C at 760 mm /Hg |
|
Vapour pressure |
105.5 at 20 deg C |
|
Vapour density (air = 1) |
1.26 |
|
Freezing point~ |
30 °C at 760 mm/Hg |
|
Completely soluble in water |
|
|
Specific gravity (water=1) |
1.16 |
|
Non combustible |
|

- This article is considered stable under normal conditions, May cause rubber to swell
- Avoid overheating
- Incompatible with strong oxidizing substances, Contact with alkaline earth metals may form explosive gases, Contact with alkali metals may form explosive gases
- See Section 5

|
Contact with skin |
In cases of severe exposure, redness and irritation may develop |
|
Contact with eyes |
Causes irritation |
|
Ingestion |
May cause gastro-intestinal disturbances |
|
Carcinogenicity |
No evidence of carcinogenic effects |

|
Ecotoxicity |
This product does not contain ingredients which are classified in the EU as dangerous for theenvironment. |
|
Mobility |
Completely soluble in water . |
|
Persistence and Biodegradability |
Its main ingredients will either dissolve rapidly and dissociate in water or are readily/inherently biodegradable. |
|
Bioaccumulation Potential |
Bioaccumulation of the components in this product is insignificant. Other Adverse Effects No environmental problems are expected when the product is used / handled correctly. |

|
Classification |
This material and/or its container must be disposed of as hazardous waste EU Waste class Disposal considerations Do not discharge into drains or the environment, dispose to anauthorised waste collection point Disposal should be in accordance with local, state or national legislation. |

| Proper Shipping Name: | ||||
| UN | ||||
| Proper Shipping Name: | Ethanoic Acid solution | |||
| UN NO. |
2789 |
|||
| Hazard Class | 8 | PackingGroup | II | |
|
Road/Rail(ADR/RID) |
||||
| Proper Shipping Name |
Ethanoic Acid solution |
|||
| ADR UN No. |
2789 |
|||
|
ADRHazardClass |
8 | Tremcard |
80GC1789-II |
|
| Sear (IMDG) | ||||
| Proper Shipping Name |
Ethanoic Acid |
|||
| IMDG UN No. |
2789 |
|||
| IMDG Hazard Class | 8 | IMDG PackGroup.: |
II |
|
| IMDG EmS | F-A, S-B | IMDG subrisk |
N/A |
|
|
IMDG Labels |
8 |
IMDG Flashpoint: |
N/A |
|
|
Air(ICAO/IATA) |
||||
| ProperShippingName |
Ethanoic Acid |
|||
| IMDG UNNo |
2789 |
|||
| IMDG HazardClass | 8 | ICAO PackingGroup |
II |
|
| ICAO subrisk | N/A | ICAO Labels: |
8+CAO |
|
| ICAO Flashpoint |
N/A |
|||
|
DOT/ CFR(USDepartment ofTransportation |
||||
|
DOTProperShippingName |
Ethanoic Acid |
|||
|
HazardousMaterial |
Ethanoic Acid |
|||
| HazardClass | 8 | IdentificationNumber: | UN2789 | |
|
Product RQ (lbs) |
N/E | DOTsubrisk: |
N/A |
|
|
DOTLabels |
8 |
DOTFlashpoint: | N/A | |
- Not classified as hazardous for transport

|
Risk Phrases |
Irritating to eyes (R35 - R10) |
|
Safety Phrases Irritant |
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice (S26)Wear suitable gloves and eye/face protection (S45) |

Text of R and S phrase codes used in this safety data sheet:-
R34 Causes burns;
R36 Irritating to eyes;
R37 Irritating to respiratory system;
R41 Risk of serious damage to eyes.
The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). The product is not sold as suitable for other applications - usage in such may cause risks not mentioned in this sheet. Do not use for other appli-cation(s) without seeking advice from manufacturer This Safety Data Sheet is provided in compliance with The Dangerous Substances Directive (67/548/EEC) This Safety Data Sheet is provided in compliance with The Dangerous Preparations Directive (88/379/EEC) This Safety Data Sheet is provided in compliance with The Safety Data Sheets Directive (2001/58EC) Composition information in accordance with Regulation (EC) No 648 /2004 of the European Parliament and of the Council of 31 March 2004 on detergents: Nonionic surfactants 5-15 % Amphoteric surfactants 5 %
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.