Mumbai Chemical
Live Chat Live Chat   Request for Quote   91 8069976675
  • Home
  • Product
  • Ship Chandlers | Ship Stores Suppliers – Mumbai
  • About Us
  • Contact
  • Blog
  • Home
  • Product
  • Ship Chandlers | Ship Stores Suppliers – Mumbai
  • About Us
  • Contact
  • Blog

Shopping Cart

0item(s) - ₹0.00
  • Home
  • Cooling Water Chemical-43
  • Corrosion Inhibitor Antifoulant for Aluminium cooling system

Request For Quote


Related products

No thumb

Anti Foaming Scale Inhibitor

No thumb

BIOCIDE for Closed Loop chilled water 210 Ltrs

No thumb

Rocor NB Liq Corrosion Scale Inhibitor

No thumb

Sodium Nitrite

No thumb

GLUTARALDEHYDE

Product categories

  • --None--
  • Agriculture-94
  • Air Lines-36
  • Asphalt Release / Products-90
  • Automobiles-41
  • Ballast Tank Chem-23
  • Boiler Chemicals-42
  • Carbon Coal Charcoal-26
  • Clean Air deodorizer-24
  • Construction Chem-67
  • Coolant Glycol Antifreeze-27
  • Cooling Water Chemical-43
  • Corrosion Inhibitor-44
  • Deck cabin galley Maintenance-25
  • Degreaser-10
  • Detergent & Soap-12
  • Drain Clean Products-29
  • Drilling Fluids & Mud Oil Field chemicals-81
  • Electrical Cleaner-30
  • Engine room Maintenance-16
  • Evaporator Treat-51
  • Floor Care ( Polish / Cleaner ) -13
  • Foundry Ind Chemicals-54
  • Fuel Treatment-70
  • Gasses-66
  • GREASES-92
  • Hand Wash / Personal care-14
  • Hold Solution-22
  • House / HOTEL & CATERING-15
  • House Ware
  • Lab Chemical-60
  • Lab Equipment-61
  • Laundry Chemicals-26
  • Leather Chem-96
  • Medicine-95
  • Metal Treatment-68
  • Oil Spill Chem & Accessory -17
  • Other
  • Paint and Cleaning solvent-18
  • Passivation-38
  • Power Plant / Heavy Industries-37
  • Pump & Accessory-21
  • Radiator and AC coil cleaner-39
  • Railway Maintenance-35
  • Raw Chemicals-19
  • RIGS Oil Field-34
  • RO Chemicals-33
  • Rubber Chemicals-93
  • Rust Clean & Protect-28
  • Safety Item-64
  • Scale Remover-11
  • Sewage Chemicals Treatment-40
  • Stains Indicator Reagents-69
  • Swimming Pool & Spa-31
  • Tank Cleaner-20
  • Test Kit For Water-62
  • Textiles / Looms-91
  • Uncategorized
  • Wall Wash Test Kit-63
  • Water Filter, Vessel, Softner, Accessory-32
  • Water Treatment-40
  • Wrench & Tools-65
Whats App Enquiry
Placeholder

Corrosion Inhibitor Antifoulant for Aluminium cooling system

QUICK OVERVIEW

Superior corrosion inhibitor developed for use in closed water circulating systems containing aluminium

Add to QuoteWorking...
Product Added to Quote
Remove from Quote
Product Added to Quote
Remove from Quote
SKU: RXSOL-40-4026-025 Category: Cooling Water Chemical-43
  • Description

Description

Corrosion inhibitor/antifoulant – aluminium cooling & closed circuit systems

RXSOL-40-4026-025 is a superior corrosion inhibitor developed for use in closed water circulating systems containing aluminium. RXSOL-40-4026-025 is based on a novel blend of organic and inorganic corrosion inhibitors, including molybdate, intended to protect steel, copper and other nonferrous metals. RXSOL-40-4026 is an ideal treatment for closed chilled water and low pressure heating systems. Whilst RXSOL-40-4026 is designed to protect systems which incorporate aluminium, it should NOT be used in systems with “Stelrad Super Plus Modular” boilers where an alternative product should be used. In all applications of  RXSOL-40-4026, where aluminium is present it is important to control the pH in the range 7-8.

Product Technical bulletin

Corrosion inhibitor/antifoulant – aluminium cooling & closed circuit systems

RXSOL-40-4026-025 is a superior corrosion inhibitor developed for use in closed water circulating systems containing aluminium. RXSOL-40-4026-025 is based on a novel blend of organic and inorganic corrosion inhibitors, including molybdate, intended to protect steel, copper and other nonferrous metals. RXSOL-40-4026 is an ideal treatment for closed chilled water and low pressure heating systems. Whilst RXSOL-40-4026 is designed to protect systems which incorporate aluminium, it should NOT be used in systems with “Stelrad Super Plus Modular” boilers where an alternative product should be used. In all applications of  RXSOL-40-4026, where aluminium is present it is important to control the pH in the range 7-8.

DOSE :::

Dosing of RXSOL-40-4026 – For systems containing no aluminium RXSOL-40-4026 should be dosed at 0.5 to 1% (5,000 – 10,000 ml/m3 ) in order to give a reserve of 50ppm of sodium molybdate.
For systems containing aluminium the dosage of 1-1.5% should be added in order to maintain a minimum reserve of 100ppm of sodium molybdate.
In certain circumstances it may be necessary to adjust the pH separately by the addition of pH conditioner. In systems requiring significant passivation higher initial dosages may be required to yield the required inhibitor residual.

Product label
RXSOL-40-4026-025 is a superior corrosion inhibitor developed for use in closed water circulating systems containing aluminium. RXSOL-40-4026-025 is based on a novel blend of organic and inorganic corrosion inhibitors, including molybdate, intended to protect steel, copper and other nonferrous metals. RXSOL-40-4026 is an ideal treatment for closed chilled water and low pressure heating systems. Whilst RXSOL-40-4026 is designed to protect systems which incorporate aluminium, it should NOT be used in systems with “Stelrad Super Plus Modular” boilers where an alternative product should be used. In all applications of RXSOL-40-4026, where aluminium is present it is important to control the pH in the range 7-8.

SIGN UP FOR OUR NEWSLETTER

Mumbai Chemical

International brand holding topmost position in marine chemicals industries. and distributing our wide range of chemicals for Marine industry internationally and other local industries and plants..

MY ACCOUNT

  • My Account
  • Checkout
  • View Cart
  • Product Listing

INFORMATION

  • About Us
  • Terms of Use
  • Club Info and FAQ’s
  • Privacy Policy

CONTACT US

  •  SEAWOOD LTD, Office Shop No-19, Palm Beach Road, Sector 54 to 58, Near Delhi Public School DPS, Nerul Seawood, Navi Mumbai, Maharashtra 400705
  •  Telephone: 918069976675
  •  E-mail: mumbaichems @ gmail.com,
    mail @ mumbaichemical.com
  •  Twitter: https://twitter.com/ChemicalMumbai
  •  Facebook: https://www.facebook.com/mumbaichemicals/
@2021 Mumbai Chemical
Close
Sign in Or Register
Forgot your password?

NEW HERE

Registration is free and easy!

  • Faster checkout
  • Save multiple shipping addresses
  • View and track orders and more
Create an account
x