Mumbai Chemical
Live Chat Live Chat   Request for Quote   91 8069976675
  • Home
  • Product
  • Ship Chandlers | Ship Stores Suppliers – Mumbai
  • About Us
  • Contact
  • Blog
  • Home
  • Product
  • Ship Chandlers | Ship Stores Suppliers – Mumbai
  • About Us
  • Contact
  • Blog

Shopping Cart

0item(s) - ₹0.00
  • Home
  • Passivation-38
  • Copper Sulfate for passivation test

Request For Quote


Related products

No thumb

Hydrofluoric Acid 40

No thumb

Alkaline Passivator

No thumb

NITRIC ACID 68% 45 Kg

No thumb

TPOL Tech 210 Ltr

Product categories

  • --None--
  • Agriculture-94
  • Air Lines-36
  • Asphalt Release / Products-90
  • Automobiles-41
  • Ballast Tank Chem-23
  • Boiler Chemicals-42
  • Carbon Coal Charcoal-26
  • Clean Air deodorizer-24
  • Construction Chem-67
  • Coolant Glycol Antifreeze-27
  • Cooling Water Chemical-43
  • Corrosion Inhibitor-44
  • Deck cabin galley Maintenance-25
  • Degreaser-10
  • Detergent & Soap-12
  • Drain Clean Products-29
  • Drilling Fluids & Mud Oil Field chemicals-81
  • Electrical Cleaner-30
  • Engine room Maintenance-16
  • Evaporator Treat-51
  • Floor Care ( Polish / Cleaner ) -13
  • Foundry Ind Chemicals-54
  • Fuel Treatment-70
  • Gasses-66
  • GREASES-92
  • Hand Wash / Personal care-14
  • Hold Solution-22
  • House / HOTEL & CATERING-15
  • House Ware
  • Lab Chemical-60
  • Lab Equipment-61
  • Laundry Chemicals-26
  • Leather Chem-96
  • Medicine-95
  • Metal Treatment-68
  • Oil Spill Chem & Accessory -17
  • Other
  • Paint and Cleaning solvent-18
  • Passivation-38
  • Power Plant / Heavy Industries-37
  • Pump & Accessory-21
  • Radiator and AC coil cleaner-39
  • Railway Maintenance-35
  • Raw Chemicals-19
  • RIGS Oil Field-34
  • RO Chemicals-33
  • Rubber Chemicals-93
  • Rust Clean & Protect-28
  • Safety Item-64
  • Scale Remover-11
  • Sewage Chemicals Treatment-40
  • Stains Indicator Reagents-69
  • Swimming Pool & Spa-31
  • Tank Cleaner-20
  • Test Kit For Water-62
  • Textiles / Looms-91
  • Uncategorized
  • Wall Wash Test Kit-63
  • Water Filter, Vessel, Softner, Accessory-32
  • Water Treatment-40
  • Wrench & Tools-65
Whats App Enquiry
Placeholder

Copper Sulfate for passivation test

QUICK OVERVIEW

Detect the presence of metallic iron and iron oxide. Chromium and nickel will not be replaced with the Copper sulfate test solution, forming the distinctive copper color on the surface in this 6 minute test.

Add to QuoteWorking...
Product Added to Quote
Remove from Quote
Product Added to Quote
Remove from Quote
SKU: RXSOL-38-6116-500 Category: Passivation-38
  • Description

Description

The copper sulfate test is used to detect the presence of metallic iron and iron oxide on the surface of materials.

Question – What solution strength is needed to copper sulfate solution can be used to determine if a metal is stainless steel or just steel ? 
Answer    – Copper sulfate (CuSO4*5H2O) + H2SO4 (anywhere from 1% to 50% is specified in various test methods).

Product Technical bulletin

The copper sulfate test is used to detect the presence of metallic iron and iron oxide on the surface of materials.

Question – What solution strength is needed to copper sulfate solution can be used to determine if a metal is stainless steel or just steel ? 
Answer    – Copper sulfate (CuSO4*5H2O) + H2SO4 (anywhere from 1% to 50% is specified in various test methods).

How does copper sulfate test for passivation work?

ANSWER : Chromium and nickel will not be replaced with the Copper sulfate test solution (which also contains sulfuric acid), only the Fe or other less noble metals. If there is free iron on the surface it will be replaced by the copper, forming the distinctive copper color on the surface in this 6 minute test. Of course, this test should only be used on austenitic stainless steel. Some people use it on other grades, but you can get false failures.
 

Spray the surface with a solution of copper sulfate in water. If free iron is present, a copper film will form. In this test, the chemical reaction is:

 Fe + CuSO4 = FeSO4 + Cu
The copper film is immediately visible.
 

Copper sulphate test: a galvanic type test in which the more noble copper plays upon less noble iron particles but not on SS.  Patches of copper sulphate shows a poorly passivated surface. Passivated parts are immersed in a Copper Sulfate solution for five minutes, rinsed and visually examined. Any copper (pink) color indicates the presence of free iron and the test is considered unacceptable.

Ferroxyl test: causes coloured iron compounds to appear as specks.

Product label

SIGN UP FOR OUR NEWSLETTER

Mumbai Chemical

International brand holding topmost position in marine chemicals industries. and distributing our wide range of chemicals for Marine industry internationally and other local industries and plants..

MY ACCOUNT

  • My Account
  • Checkout
  • View Cart
  • Product Listing

INFORMATION

  • About Us
  • Terms of Use
  • Club Info and FAQ’s
  • Privacy Policy

CONTACT US

  •  SEAWOOD LTD, Office Shop No-19, Palm Beach Road, Sector 54 to 58, Near Delhi Public School DPS, Nerul Seawood, Navi Mumbai, Maharashtra 400705
  •  Telephone: 918069976675
  •  E-mail: mumbaichems @ gmail.com,
    mail @ mumbaichemical.com
  •  Twitter: https://twitter.com/ChemicalMumbai
  •  Facebook: https://www.facebook.com/mumbaichemicals/
@2021 Mumbai Chemical
Close
Sign in Or Register
Forgot your password?

NEW HERE

Registration is free and easy!

  • Faster checkout
  • Save multiple shipping addresses
  • View and track orders and more
Create an account
x