Description
It is a well – balanced blend for boiler water treatment products, resulting in a scale and corrosion control by one shot operation. A one-step treatment to control the formation of rust and scale in low pressure and auxillary boilers with working pressure up to 20 bars.
The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide.
Product Technical bulletin
BOILER WATER TREATMENT
UNIVERSAL–ONE SHOT (RXSOL-50-5001-025)
Product Description:-RXSOL-50-5001-025 is a well-balanced blend for boiler water treatment, resulting in a scale and corrosion control by one simple operation.
Function Mechanism:
Alkalinity Control:-This components of RXSOL-50-5001-025 chemically precipitate the hardness of salts like Calcium & Magnesium & neutralizes the acidic conditions.
Hardness Control:-RXSOL-50-5001-025 provides phosphate reserve to effectively react with and precipitate the hardness salts introduces with the feed water.
Sludge Conditioner:-RXSOL-50-5001-025 component will preventing the sludge from adhering to metals surfaces. Boiler sludge can only be removed by blow down.
Oxygen Scanvangers:-Catalyzed liquid of RXSOL-50-5001-025 controls the formation of oxygen to protects boiler & steam line corrosion protection. As an additional benefits it will assist to neutralize dissolved carbon dioxide. In this way RXSOL-50-5001-025 preventing oxygen “Pitting” corrosion.
Application , Dosage:- RXSOL-50-5001-025 is strongly alkaline. RXSOL-50-5001-025 is best applied neat or diluted with any con –venient strength on a continuous basis using a suitable chemicals pump . The product should be applied to the boiler feed tank or feed line to ensure adequate mixing. The dosage rate of RXSOL-50-5001-025 is dependent on boiler operating condition, Feed 2-3 Ltrs of RXSOL-50-5001-025 solution for per thousand Ltr of boilers water Then control the system by Periodic Alkalinity test procedure. If p-Alkalinity is below 200 ppm increase the ratio of RXSOL-50-5001-025 solution. If p-Alkalinity is above 400 ppm reduce the concentration of RXSOL-50-5001-025 solution by dilution with water.
Control Procedure:- Control is by simple boiler water tests or RX CLEANSERS can provide a suitable test kits for this purpose.
Product Properties:-
Appearance |
Clear liquid |
|
Density |
In g/cm3 at 15°C: 1.1±0.02 |
|
Solubility In Water |
Complete |
|
pH (1 Vol %) |
>13 |
|
Compatibility |
|
|
Metal |
Corrosive to aluminium, magnesium, zinc and tin. |
|
Rubber |
No known effect. |
|
Packaging |
Product : RXSOL-50-5001-025 |
Size (in litres) : As per demand. |
Characteristics:-
- Convenient liquid treatment, which provides the basic alkalinity on which successful water treatment depends.
- Provides optimum conditions for hardness control to function.
- Neutralizes acid conditions.
- Will assist in keeping silica in suspension.
- Simple test to determine level of treatment.
- Can be used in boilers of all pressures.
- Can be used as a neutralizer after acid cleaning operations.
- Suitable for use with all auxiliary boilers; waste heat units; economizers, package boilers, smoke and water tube boilers.
- Dispersant action suspends sludge and sediment particles for efficient blow down.
- Oxygen scavenging for optimum protection.
- Protects boiler, steam lines, condensate lines and feed water lines from corrosion.
- Fast action due to catalyst.
- Simple test to determine level of treatment.
Packaging, Handling, First Aid & Storage:-
RXSOL-50-5001-025 is generally supplied in drums containing 25 / 210 Ltrs. Avoid contact with skin and eyes wear goggles & PVC gloves when handling. Keep an eye wash bottle close to the point of use. Do not take internally.On contact with Skin/Cloth, wash immediately with cupious amount of water. If eyes are affected they should be washed with water for at least 15 Minutes and medical attention sought immediately. If swallowed do not induces vomiting give plenty of water and call doctor immediately.
**Keep drums tightly closed when not in use.**
Product label
RXSOL-50-5001-025 It is a well – balanced blend for boiler water treatment products, resulting in a scale and corrosion control by one shot operation.
The dosage rate is dependent on bioler operating condition, feed 2-3 ltrs of RXSOL-50-5001-025 solution for per thousand ltr of bioler water then control the system by periodic Alkalinity test procedure.