Mumbai Chemical
Live Chat Live Chat   Request for Quote   91 8069976675
  • Home
  • Product
  • Ship Chandlers | Ship Stores Suppliers – Mumbai
  • About Us
  • Contact
  • Blog
  • Home
  • Product
  • Ship Chandlers | Ship Stores Suppliers – Mumbai
  • About Us
  • Contact
  • Blog

Shopping Cart

0item(s) - ₹0.00
  • Home
  • Lab Chemical-60
  • Silver Nitrate Soln. LR

Request For Quote


Related products

No thumb

Fluoride Ion Solution 0.0100 Molar

No thumb

Acetone LR

No thumb

Hydrochloric Acid LR 500 ml

No thumb

Potassium Permagnate 500 Gram

No thumb

Chloride Soln 100 PPM

Product categories

  • --None--
  • Agriculture-94
  • Air Lines-36
  • Asphalt Release / Products-90
  • Automobiles-41
  • Ballast Tank Chem-23
  • Boiler Chemicals-42
  • Carbon Coal Charcoal-26
  • Clean Air deodorizer-24
  • Construction Chem-67
  • Coolant Glycol Antifreeze-27
  • Cooling Water Chemical-43
  • Corrosion Inhibitor-44
  • Deck cabin galley Maintenance-25
  • Degreaser-10
  • Detergent & Soap-12
  • Drain Clean Products-29
  • Drilling Fluids & Mud Oil Field chemicals-81
  • Electrical Cleaner-30
  • Engine room Maintenance-16
  • Evaporator Treat-51
  • Floor Care ( Polish / Cleaner ) -13
  • Foundry Ind Chemicals-54
  • Fuel Treatment-70
  • Gasses-66
  • GREASES-92
  • Hand Wash / Personal care-14
  • Hold Solution-22
  • House / HOTEL & CATERING-15
  • House Ware
  • Lab Chemical-60
  • Lab Equipment-61
  • Laundry Chemicals-26
  • Leather Chem-96
  • Medicine-95
  • Metal Treatment-68
  • Oil Spill Chem & Accessory -17
  • Other
  • Paint and Cleaning solvent-18
  • Passivation-38
  • Power Plant / Heavy Industries-37
  • Pump & Accessory-21
  • Radiator and AC coil cleaner-39
  • Railway Maintenance-35
  • Raw Chemicals-19
  • RIGS Oil Field-34
  • RO Chemicals-33
  • Rubber Chemicals-93
  • Rust Clean & Protect-28
  • Safety Item-64
  • Scale Remover-11
  • Sewage Chemicals Treatment-40
  • Stains Indicator Reagents-69
  • Swimming Pool & Spa-31
  • Tank Cleaner-20
  • Test Kit For Water-62
  • Textiles / Looms-91
  • Uncategorized
  • Wall Wash Test Kit-63
  • Water Filter, Vessel, Softner, Accessory-32
  • Water Treatment-40
  • Wrench & Tools-65
Whats App Enquiry
Placeholder

Silver Nitrate Soln. LR

QUICK OVERVIEW

This RXSOL standard solution make Colloidal Turbidity by refraction of the liquid. And Colloidal matter indicates hydrocarbons, chlorides and other residues.

Add to QuoteWorking...
Product Added to Quote
Remove from Quote
Product Added to Quote
Remove from Quote
SKU: RXSOL-60-6106-500 Category: Lab Chemical-60
  • Description

Description

Laboratory GRADE materials ::: 

Chloride test:

50cc un-filtered wash add to 30 cc distilled water shake well to dissolve salt and then filter qualitatively.

Colloidal particles are not simple molecules but physical aggregation of molecules . They readily pass through ordinary filter paper.. Turbidity is a measure of the refraction of the liquid. Colloidal matter indicates hydrocarbons, chlorides and other residues.



Note: Methanol cannot dissolve salt or loosen the sodium cation/chloride anion from the NaCL ionic bond. -only water with high solvent power and high dielectric constant can do this. NaCL crystal is extremely strong and rigid. A Sodium ion is equally attracted to 6 Chloride ions.

To this 80cc mixture— add 1/2 cc silver nitrate( strength 10%) plus 2cc nitric acid ( strength 20%) plus 17.5 cc di water to make 100 cc total.

Shake and stand for 5 minutes. Compare milkiness with a standard comparator of 1ppm made as follows:

50cc Methanol + 4cc standard Chloride soln ( strength 10ppm ) + 1/2 cc Silver Nitrate ( strength 10%) + 2cc Nitric acid ( strength 20%) + 43.5 cc DI water to make total 100cc solution . Memorise this milkiness as the failing standard for the current voyage.

(for 0.5 ppm comparator put 2 cc of standard chloride soln, for 0.250 ppm put 1 CC.) For 2 ppm put 8cc NaCl —-for 4ppm put 16cc NaCl.



Why Nitric acid ??— Nitric acid parts the silver vide the assaying process as chemically silver is not active and dissolves only in strong Nitric acid or H2So4.

The method of not involving Nitric acid in the Chloride test could pass a ship staff tank WWT , while a shore gas ion chromatograph will fail the sample for Mono Ethylene Glycol fibre grade. Nitric acid decomposes Sodium Cyanide and Sodium Sulphide which otherwise form precipitate with AgNO3 and thus interfere with the lab test.

Product Technical bulletin

Product label
Chloride test:
50cc un-filtered wash add to 30 cc distilled water shake well to dissolve salt and then filter qualitatively.
Colloidal particles are not simple molecules but physical aggregation of molecules . They readily pass through ordinary filter paper.. Turbidity is a measure of the refraction of the liquid. Colloidal matter indicates hydrocarbons, chlorides and other residues.

Note: Methanol cannot dissolve salt or loosen the sodium cation/chloride anion from the NaCL ionic bond. -only water with high solvent power and high dielectric constant can do this. NaCL crystal is extremely strong and rigid. A Sodium ion is equally attracted to 6 Chloride ions.
To this 80cc mixture— add 1/2 cc silver nitrate( strength 10%) plus 2cc nitric acid ( strength 20%) plus 17.5 cc di water to make 100 cc total.
Shake and stand for 5 minutes. Compare milkiness with a standard comparator of 1ppm made as follows:
50cc Methanol + 4cc standard Chloride soln ( strength 10ppm ) + 1/2 cc Silver Nitrate ( strength 10%) + 2cc Nitric acid ( strength 20%) + 43.5 cc DI water to make total 100cc solution . Memorise this milkiness as the failing standard for the current voyage.
(for 0.5 ppm comparator put 2 cc of standard chloride soln, for 0.250 ppm put 1 CC.) For 2 ppm put 8cc NaCl —-for 4ppm put 16cc NaCl.

Why Nitric acid ??— Nitric acid parts the silver vide the assaying process as chemically silver is not active and dissolves only in strong Nitric acid or H2So4.
The method of not involving Nitric acid in the Chloride test could pass a ship staff tank WWT , while a shore gas ion chromatograph will fail the sample for Mono Ethylene Glycol fibre grade. Nitric acid decomposes Sodium Cyanide and Sodium Sulphide which otherwise form precipitate with AgNO3 and thus interfere with the lab test.

SIGN UP FOR OUR NEWSLETTER

Mumbai Chemical

International brand holding topmost position in marine chemicals industries. and distributing our wide range of chemicals for Marine industry internationally and other local industries and plants..

MY ACCOUNT

  • My Account
  • Checkout
  • View Cart
  • Product Listing

INFORMATION

  • About Us
  • Terms of Use
  • Club Info and FAQ’s
  • Privacy Policy

CONTACT US

  •  SEAWOOD LTD, Office Shop No-19, Palm Beach Road, Sector 54 to 58, Near Delhi Public School DPS, Nerul Seawood, Navi Mumbai, Maharashtra 400705
  •  Telephone: 918069976675
  •  E-mail: mumbaichems @ gmail.com,
    mail @ mumbaichemical.com
  •  Twitter: https://twitter.com/ChemicalMumbai
  •  Facebook: https://www.facebook.com/mumbaichemicals/
@2021 Mumbai Chemical
Close
Sign in Or Register
Forgot your password?

NEW HERE

Registration is free and easy!

  • Faster checkout
  • Save multiple shipping addresses
  • View and track orders and more
Create an account
x