RXSOL pH Boosters are liquid alkaline formulation,used as alkalinity source for boiler feed water. It is synergized with properties of pH boosting and water conditioning.
Morpholine have unique pH adjusting qualities and uses and distribution throughout the steam plant helps to protect from corrosion. Morpholine is often used in conjunction with low concentrations of hydrazine or ammonia to provide a comprehensive all-volatile treatment chemistry for corrosion protection for the steam systems of such plants. Morpholine decomposes reasonably slowly in the absence of oxygen at the high temperatures and pressures in these steam systems.
Boiler water pH booster or alkalinity builder is a multipurpose Boiler Water Treatment Chemical that increases the alkalinity and pH of boiler water for corrosion inhibition and also aids in removal of sludge or boiler deposits and prevention of scaling in boiler tubes. Normally the Boiler feed water pH should be at 9.5-10 for avoiding boiler tubes corrosion or rusting due to acidic attack.
RXSOL-40-5024-020 have antiscalant property which will help to formation of scale inside the boiler. This makes it profitable for users by savings of power and labor, and increase in production. As Uses of antiscalants is a prime necessity to meet up with production targets.
pH booster is an alkaline liquid formulation designed to increase alkalinity of feed water of boiler. It is also used to reduce corrosion of feed water tank,lines & pump.
CORROSION REDUCTION
pH booster Increases ph of the feed water reducing corrosiveness.it also increases alkalinity in boiler water reducing scaling & corrosion of the boiler metal.
EASY SLUDGE REMOVAL
pH booster is helps in formation of non adherent sludge.it fluidises the sludge which is then removed easily during normal blow-down. non- toxic and non-corrosive liquid formulation and therefore can be handled easily.
RXSOL pH Boosters are dosed depending upon the feed water characteristic and alkalinity requirement. It is compatible with all other treatment chemicals. It is dosed exactly as per the dosage rate and method of RXSOL-50-5001-025
EASY TO HANDLE
pH booster is non- toxic liquid formulation and therefore can be handled easily. pH booster should be dosed continuously. Dose the dilute solution in boiler feed water line.
| Properties | Unit | Typical Value |
| Form and Appearance | - | Clear Colorless Liquid |
| Odor | - | Characteristic |
| pH (neat) | pH | Alkaline |
| Solubility | - | Completely Soluble in Water |
Key Features & Benefits:-
Minimizes corrosion of feed water tank, lines and pump
Imparts water and sludge conditioning to minimize scaling and deposition
Compatible with other treatment Chmicals
Completely biodegradable chemicals
Its antiscale property helps and Prevent from Scaling
Minimum downtime required for descaling
Multipurpose,therefore easy to use
Proper maintenance of boiler saves Power / Fuel saving upto 70%. Formation of Scale is major issue and contol of scale makes Effectively heat transfer which Increase productivity.
STORAGE & HANDLING
pH booster should be stored in an air tight container away from direct heat.
Always store at cool & dry place.
Handle using goggles & do not breathe in the vapours.
Wash thoroughly in case of contact. Do not swallow.
pH Control
Maintenance of proper pH throughout the boiler feedwater, boiler, and condensate systems is essential for corrosion control. Most low-pressure boiler system operators monitor boiler water alkalinity because it correlates very closely with pH, while most feedwater, condensate, and high-pressure boiler water requires direct monitoring of pH. Control of pH is important for the following reasons:
- corrosion rates of metals used in boiler systems are sensitive to variations in pH
- low pH or insufficient alkalinity can result in corrosive acidic attack
- high pH or excess alkalinity can result in caustic gouging/cracking and foaming, with resultant carryover
- speed of oxygen scavenging reactions is highly dependent on pH levels
The pH or alkalinity level maintained in a boiler system depends on many factors, such as sys-tem pressure, system metals, feedwater quality, and type of chemical treatment applied.
The corrosion rate of carbon steel at feedwater temperatures approaches a minimum value in the pH range of 9.2-9.6 . It is important to monitor the feedwater system for corrosion by means of iron and copper testing. For systems with sodium zeolite or hot lime softened makeup, pH adjustment may not be necessary. In systems that use deionized water makeup, small amounts of caustic soda or neutralizing amines, such as morpholine and cyclohexylamine, can be used.
In the boiler, either high or low pH increases the corrosion rates of mild steelThe pH or alkalinity that is maintained depends on the pressure, makeup water characteristics, chemical treatment, and other factors specific to the system.
The best pH for protection of copper alloys is somewhat lower than the optimum level for carbon steel. For systems that contain both metals, the condensate and feedwater pH is often maintained between 8.8 and 9.2 for corrosion protection of both metals. The optimum pH varies from system to system and depends on many factors, including the alloy used
To elevate pH, neutralizing amines should be used instead of ammonia, which (especially in the presence of oxygen) accelerates copper alloy corrosion rates. Also, amines form protective films on copper oxide surfaces that inhibit corrosion.

| Product Name | RXSOL-33-5024-250 |
| Product Type | pH Booster Morpholine Base |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point ::: Mumbai, Kandla, Kolkata, Chennai, Vizag, Fujairah, Muscat, Kenya, Canada
| Phone | +91 22 65113333 / 5555 / 9999 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| mail@rxmarine.com |

COMPONENTS All ingredients not precisely identified are proprietary.
| Name | Weight % |
| Morpholine | 10-15 |
| Hydrazine | 1-5 |
| Proprietary Blend of anti scalants, pH boosters, etc | >80 |

EMERGENCY OVERVIEW:
| Appearance | Liqud |
| Odor | Characteristic |
POTENTIAL HEALTH EFFECTS
| EYES | Slight irritation may occur |
| SKIN | Slight irritaion may occur |
| INGESTION | Slight irritaion may occur |
| INHALATION | Slight irritaion may |
|
ACUTE AND occur CHRONIC HEALTH HAZARDS |
None known. |
|
MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE |
None known. |
CARCINOGENICITY
| OSHA | n/a |
| IARC | n/a |
| ACGIH | n/a |
| OTHER | n/a |
| NTP | n/a |

|
EYES: |
Flush eyes thoroughly with running water for 15 minutes while keeping the eyelids wide open. Consult physician if redness or irritation persists. |
| SKIN: | Wash with soap and water. Cold water may be used. If irritation develops seek medical attention |
|
INGESTION: |
Do NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. If large quantities of this material are swallowed, call a physician immediately. Loosen tight clothing such as a collar, tie, belt or waistband. |
|
INHALATION: |
If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention. |

| SUITABLE EXTINGUISHING MEDIA |
Any |
| EXTINGUISHING MEDIA WHICH MUST NOT BE USED FOR SAFETY REASONS |
None |
| SPECIAL EXPOSURE HAZARDS IN A FIRE |
None |
| SPECIAL PROTECTIVE EQUIPMENT FOR FIRE-FIGHTERS |
None |
| OTHER INFORMATION | None |

| PERSONAL PRECAUTIONS | Follow protective measures provided in sections 5 and 8 Keep away materials and products which are incompatible with product specified in section 10 |
| ENVIRONMENTAL PRECAUTIONS | Rinse spilled product to dillute areas of direct contact. |
| METHODS FOR CLEAN UP |
Wear suitable clothing and protective equipment Recover or mop up excess material and reuse wherever possible. Absorb unusable product with suitable material and dispose of in accordance with Section 13. |

HANDLING
Maintain good housekeeping practices
Wash hands after use
Avoid contact with potable water or food
STORAGE
Keep in a dry place
Keep away from direct sunlight
Keep away from heat
Keep away from incompatible products specified in section 10
Keep only in the original container at temperature not exceeding 40C (104F)

| ENGINEERING CONTROLS: | NA |
| VENTILATION: | Local exhaust, mechanical exhaust recommended |
| RESPIRATORY PROTECTION: | Dust filter mask recommended |
| EYE PROTECTION: | ANSI approved safety glasses with side protection or goggles. |
| SKIN PROTECTION: | Wear suitable protective clothing |
| HYGIENIC PRACTICES: | Handle in accordance with good hygiene and safety practice. |

GENERAL INFORMATION
| APPEARANCE: |
Liquid |
| ODOR: | Characteristic |
IMPORTANT HEALTH SAFETY AND ENVIRONMENTAL INFORMATION
| pH: | 5-7 |
| BOILING POINT | NA |
| FLASH POINT | NA |
| MELTING POINT | 851 C |
|
FLAMMABILITY (SOLID, GAS) |
Non flammable |
|
EXPLOSIVE PROPERTIES |
Non-explosive |
|
VAPOR PRESSURE: |
NA |
| VAPOR DENSITY: | NA |
| BULK DENSITY | NA |
| EVAPORATION | NA |
|
SOLUBILITY IN WATER: |
Soluable in water |
|
DECOMPOSITION TEMPERATURE |
NA |
| VISCOSITY: | NA |
| SPECIFIC GRAVITY | 1.20 |

| STABILITY: | Stable under normal conditions of use. |
|
CONDITIONS TO AVOID: |
None |
|
INCOMPATIBILITY (MATERIAL TO AVOID): |
Acid |
|
HAZARDOUS DECOMPOSITION OR BY-PRODUCTS: |
Not Known |
|
HAZARDOUS POLYMERIZATION: |
NA |
|
CONDITIONS TO AVOID: |
NA |

TOXICOLOGICAL DATA:
|
ACUTE ORAL TOXICITY |
4090mg/kg (rat) |
|
ACUTE INHALATION TOXICITY |
causes severe irritation of the respiratory tract |
|
ACUTE DERMAL IRRITATION/CORRO SION |
Not Known |
| SKIN IRRITATION | Causes slight irritation |
| EYE IRRITATION | Causes severe irritation of the eyes |
| SENSITIZATION | None |
| CHRONIC TOXICITY | NA |
|
CHRONIC TOXICITY/ CARCINOGENIC DESIGNATION: |
Prolonged or repeated skin contact may produce severe irritation or dermatitis. |

ECOTOXICITY EFFECTS:
| ACUTE TOXICITY: | None known |
| MOBILITY: | NA |
| PERSISTENCE AND DEGRADABILITY: |
None known |
| BIOACCUMULATIVE POTENTIAL: | Is not known to accumulate |

| WASTE TREATMENT: | Dispose of within current local and state regulations. No special method required. |
| PACKAGING TREATMENT: | Consult federal, state, and local regulations regarding the proper disposal of emptied containers. |
| RCRA HAZARD CLASS: |
NA |

U.S. DEPARTMENT OF TRANSPORTATION
| Chemicals Not Hazardous |
|
PROPER SHIPPING NAME: |
Otherwise Indexed (NOI) |
| HAZARD CLASS: |
Not Regulated |
| ID NUMBER: | NA |
| LABEL STATEMENT: | None |
WATER TRANSPORTATION
| Chemicals Not Hazardous |
|
PROPER SHIPPING NAME: |
Otherwise Indexed (NOI) |
| HAZARD CLASS: | Not Regulated |
| ID NUMBER: | NA |
|
LABEL STATEMENT: |
None |
AIR TRANSPORTATION
| Chemicals Not Hazardous |
|
PROPER SHIPPING NAME: |
Otherwise Indexed |
| HAZARD CLASS: | Not Regulated |
| ID NUMBER: | NA |
| LABEL | None |

Preparation does not contain ingredients listed as a dangerous substance in Annex 1 of the EEC directive 67/548.

KEEP OUT OF REACH OF CHILDREN
Although the information and recommendations set forth in this sheet are believed to be correct as of the date hereof, RX Marine International makes no representation as to the completeness or accuracy of such information and recommendations. RX Marine International shall in no event be responsible for any damages of whatsoever nature directly or indirectly resulting from the publication or use of or reliance upon such information and recommendations. You are encouraged to advise anyone working with or exposed to such products of the information contained herein.
No Warranty, either expressed or implied, of merchantability or fitness or of any other nature with respect to the product or to the information and recommendations herein made hereunder.
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.