Polyacrylate material of low molecular weight. Non-volatile used for scale inhibition in sea water treatment. The product is miscible with water in all proportions. And is clear Liquid. Scale Hardness Stabilizer Hardness Control is specialized Water treatment product to KEEP water Clear and Clean SLUDGE FREE.
RXSOL-33-5027-025 Scale Hardness Stabilizer is basically Polyacrylate phosphates combination with synthetic polymers. Very easy to use, provides flexibility in system operation and control over the operation of the auxiliary. The tool is designed to maintain the cleanliness of the system at unstable as feedwater.
To be most effective to prevent corrosion and scaling RXSOL-33-5027-025 Scale Hardness Stabilizer should be constantly adding to the system with a dosing devices. Less preferable to use gravitational dosing device, because preparation can evaporate when the water returns into the tank cascade.
Regularly enter solutions RXSOL-33-5027-025 Scale Hardness Stabilizer with a dosing device in feedwater recirculation outlet below which returns cascading water in the tank. If there is no recirculation of feedwater, the RXSOL-33-5027-025 Scale Hardness Stabilizer should be submitted in suction tube feeding pump. When using gravity dispenser the RXSOL-33-5027-025 Scale Hardness Stabilizer should be fed to the point of feed water tank or in cascade.
|
Appearance |
: Clear liquid |
|
Specific gravity at 25 º C (77 º F) |
: 1.2 |
|
Fire |
: off |
|
Freezing temperature |
: -6.6 º C (20 º F) |
|
pH |
: 5-7 |
|
Stability after freeze / that |
: yes |
RXSOL-33-5027-025 Scale Hardness Stabilizer supply line should be higher than normal water level (about 1 meter) and as close as possible to the fence of water nutrient pump. RXSOL-33-5027-025 Scale Hardness Stabilizer to be diluted in distilled water or condensate in the dispensing tank and gradually continuously fed for 24 hours, keeping the system demand. The daily dosage is depend on the volume of the system, the condensate quality and purity, as well as the quality and quantity of the feed water system. For standard operating systems the dosage RXSOL-33-5027-025 Scale Hardness Stabilizer is about 1 liter a day.
Very large systems or in non-standard conditions will have a greater need for preparation. Many factors can affect the initial dose of the RXSOL-33-5027-025 Scale Hardness Stabilizer. The recommended initial dose of 2.5 to 5 liters per tonne of water system. After the initial filling of the product during operation of the system on a daily basis should perform a test to adjust the dosage. Low quality feedwater demands increase quantities of preparation.
The main objective of the program - to prevent fouling. The most effective way to fight c deposits is to use distilled water feed. RXSOL-33-5027-025 Scale Hardness Stabilizer created for removing water hardness instability.
Blowdown
Purge procedure is necessary for the effectiveness of any treatment program and system watershall be in accordance recommendations manufacturer's instructions. Purging is required to remove the precipitate dissolved and suspended solids. Normal regular purging with sufficient neutral of conductivity 700 micromho. A higher rate of conductivity (above 700 micromho) frequency blowdown should be increased. Additionally, it is recommended to wash weekly collector or separator pair (if any) to reduce the accumulation of sludge.
Did you know, how to keep system scale and corrosion free, water CLEAR and Sludge free?
RXSOL-33-5027-025 Scale Hardness Stabilizer contains Polycarboxylate Phosphate and synthetic low molecular wt polymer to control sludge which results in the clean boiler water. USES of RXSOL-33-5027-025 control Hardness and provide tolerance of feedwater quality fluctuations.
Chemically one part of The RXSOL-33-5027-025 polymers keeping the sludge particles soft by increasing property of nonadherent which also resulting smooth blowdown during cleaning and maintenance operation.
While Other part of Phosphate which is used in RXSOL-33-5027-025 serve as deposit control agents by Iron dispersancy, main cause of sequestering deposits.
USES of RXSOL-33-5027-025 during sea water treatment, can help and keep WATER CLEAN and CLEAR.
![]()
| Product Name | : | RXSOL-33-5027-025 |
| Product Type | : | SCALE HARDNESS STABILIZER |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point : Mumbai, Kandla, Kolkata, Chennai, Vizag, Surat, Fujairah, Muscat, Nairobi
| Phone | : | +91 22 65113333 / 5555 / 9999 / 27611360 |
| Fax | : | +91 22 2781 1318 :::AOH :0091 9821214367 |
| : | mail@rxmarine.com |
![]()
|
Chemica Name |
Concentration |
|
Polycarboxylate LOW Molecular Wt Mixture |
30-45 |
| Polyacrylate Sodium Based | 18-27 |
| Proprietory Blend of POLYMER | 27-30 |
*See Section 16
![]()
|
Odour |
Odourless. |
|
Appearance |
Clear, soluble in water. |
|
Contact with eyes |
Prolonged exposure may cause abrasive irritation of the eyes. |
|
Contact with skin |
In cases of severe exposure, irritation may develop. |
|
Inhalation |
Prolonged exposure may cause abrasive irritation of the mucous membranes. |
|
Ingestion |
The ingestion of significant quantities may cause gastro-intestinal disturbances. |
![]()
|
Contact with skin |
Wash affected area with plenty of soap and water |
|
Contact with eyes |
If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes Irrigate eyes thoroughly whilst lifting eyelids.When in doubt or symptoms persist, seek medical attention |
|
Ingestion |
Never give anything by mouth to an unconscious person.Give water or milk to drink.When in doubt or symptoms persist, seek medical attention |
|
Inhalation |
Remove patient to fresh air.Seek medical attention if irritation persists |
|
General |
In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45) |
![]()
- Non-combustible solid
- Decomposition products may include phosphorous compounds
- Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions
![]()
|
Personal Precautions |
Wear protective clothing as per section 8.Avoid raising dust. |
|
Environmental Precautions |
No special precautions are required for this product. |
|
Clean Up Actions |
Sweep or shovel-up spillage and remove to a safe place.Wash spill site with water and detergent. |
|
Special Precautions |
Wear protective clothing as per section 8. |
![]()
|
Handling |
The usual precautions for handling chemicals should be observed. |
|
Storage |
Keep only in the original container in a cool, well ventilated place (S3/9/49). |
![]()
|
Exposure Limits |
There are no recommended or established controls for this product. |
|
Occupational exposure controls |
Wear suitable dust mask e.g. to BS 2091.Wear suitable protective clothing, including eye/face protection and gloves (plastic or rubber are recommended). |
![]()
Gloves Goggles Suit No_Smoking
![]()
|
Odour |
Odourless |
|
Vapour pressure |
not known |
|
Melting point |
>600 °C at 760 mm /Hg - Water solubility ~100 g/l |
|
Appearance |
: Clear liquid |
|
Specific gravity at 25 º C (77 º F) |
: 1.2 |
|
Fire |
: off |
|
Freezing temperature |
: -6.6 º C (20 º F) |
|
pH |
: 5-7 |
|
Stability after freeze / that |
: yes |
![]()
- This article is considered stable under normal conditions+9
- Avoid contact with moist air
- See Section 5
![]()
|
Toxicological information |
LD50 (dermal) : 7250 mg/kg |
|
Inhalation |
May cause irritation |
|
Contact with skin |
In cases of severe exposure, redness and irritation may develop |
|
Contact with eyes |
May cause irritation |
|
Ingestion |
No effects for small dosage. Large dose effects not known |
|
Carcinogenicity |
No evidence of carcinogenic effects |
![]()
|
Ecotoxicity |
No hazard to the aquatic environment |
|
Mobility |
Completely soluble in water |
|
Persistence and Biodegradability |
Degrades by hydrolysis |
|
Bioaccumulation Potential |
Bioaccumulation is insignificant |
|
Other Adverse Effects |
No environmental problems are expected when the product is used / handled correctly. In its intended use, the product will not be released into the environment.Presents little or no hazard to the environment. |
![]()
|
Classification |
EU Waste class |
|
Disposal considerations |
Follow waste treatment method Do not discharge directly into drains or the environment. dispose to an authorised waste collection point Disposal should be in accordance with local, state or national legislation |
![]()
- Not classified as hazardous for transport
![]()
|
Risk Phrases |
Not applicable |
|
Safety Phrases |
Not applicable |
![]()
The information provided about the product on this Safety Data Sheet has been compiled from knowledge of The individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product In terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). This Safety Data Sheet is provided in compliance with The Directive (67/548/EEC) This Safety Data Sheet is provided in compliance with The Preparations Directive (88/379/EEC) This Safety Data Sheet is provided in compliance with The Safety Data Sheets Directive (2001/58EC)
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.