Sodium bromide is used to prepare dense fluids used in oil wells, Because of its density, sodium bromide is used as a completion, work-over and packer fluid in oilfield applications.
And Sodium bromide can be used as a source of the chemical element bromine. This can be accomplished by treating an aqueous solution of NaBr with chlorine gas. When used with an oxidizer, such as sodium hypochlorite, sodium bromide is an excellent biocide. It has wide industrial applications, including water treatment and pulp & paper manufacturing.
Sodium Bromide is a pesticide used in formulating liquid sodium bromide microbiocides for the control of algal, bacterial and fungal slimes in industrial water treatment as well as municipal wastewater applications.
Other applications for sodium bromide also include photography and medicines.
Sodium Bromide Solution is an inorganic compound with the formula NaBr.nH2O. It is a high-boiling colorless, odorless liquid that resembles sodium chloride. It is a widely used source of the bromide ion and has many applications. Sodium Bromide (NaBr) liquid is a single salt used to form clear- brine workover and completion fluids.
Sodium Bromide fluids are used where formation pressures require densities from 8.4 to 12.8 lb/gal (1,007 to 1,534 kg/m) or where the formation waters contain high concentrations of bicarbonate and sulfate ions. NaBr can be mixed with NaCl to obtain densities up to 12.8 lb/gal (1,534 kg/m). NaBr/NaCl systems are more economical than pure NaBr solutions.
Sodium bromide stockist and supplier in INDIA and Exporter to Middle East. For use in completion and oil drilling fluids and for industrial use. bromide is a salt with the formula NaBr, widely used as an anticonvulsant in the late 19th and early 20th centuries. Its action is due to the bromide ion (potassium bromide is equally effective). Sodium bromide (NaBr) is a single salt clear brine fluid. It is available in 40% to 46% concentration.

| Product Name | SODIUM BROMIDE Solution |
| Part Number | RXSOL-81-1617-250 |
Company Details:....
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Branch : Kandla, Mumbai , Chennai, Vizag, Kolkata, UAE , OMAN , CANADA and KENYA
| Phone | +91 22 20871200 - 1400 |
| Fax | +91 22 27612100 :::AOH :0091 9821214367 |
| mail@rxmarine.com | |
| Website | www.rxmraine.com |

| Component | CAS No | Weight % |
| Sodium bromide | 7647-15-6 | >45 |

| Classification | This chemical is considered hazardous by the 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) |
| Label elements | |
| Signal Word | Warning |
| Hazard Statements |
May cause drowsiness or dizziness
Suspected of damaging fertility. Suspected of damaging the unborn child
May cause damage to organs through prolonged or repeated exposure
|
| Precautionary Statements |
Prevention
Obtain special instructions before use
Do not handle until all safety precautions have been read and understood
Use personal protective equipment as required
Do not breathe dust/fume/gas/mist/vapors/spray
Use only outdoors or in a well-ventilated area
Response
IF exposed or concerned: Get medical attention/advice
Inhalation
IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing
Storage
Store locked up
Store in a well-ventilated place. Keep container tightly closed
Disposal
Dispose of contents/container to an approved waste disposal plant
|
| Hazards not otherwise classified (HNOC) | None identified |

Description of first aid measures
| General Advice | If symptoms persist, call a physician. |
| Eye Contact | Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Getmedical attention. |
| Skin Contact | Wash off immediately with plenty of water for at least 15 minutes. If skin irritationpersists,call a physician. |
| Inhalation | Remove to fresh air. If not breathing, give artificial respiration. Get medical attentionif symptoms occur. |
| Ingestion | Clean mouth with water and drink afterwards plenty of water. Get medical attentionif symptoms occur. |
| Most important symptoms and effects | None reasonably foreseeable |
| Notes to Physician | Treat symptomatically |

Extinguishing media
| Suitable Extinguishing Media | Use extinguishing measures that are appropriate to local circumstances and thesurrounding environment. |
| Unsuitable Extinguishing Media | No information available |
| Flash Point | No information available |
| Method | No information available |
| Autoignition Temperature |
Highly flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard.
In a fire or if heated, a pressure increase will occur and the container may burst, with the
risk of a subsequent explosion. The vapor/gas is heavier than air and will spread along
the ground. Vapors may accumulate in low or confined areas or travel a considerable
distance to a source of ignition and flash back.
Highly flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard.
In a fire or if heated, a pressure increase will occur and the container may burst, with the
risk of a subsequent explosion. The vapor/gas is heavier than air and will spread along
the ground. Vapors may accumulate in low or confined areas or travel a considerable
distance to a source of ignition and flash back.
Highly flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard.
In a fire or if heated, a pressure increase will occur and the container may burst, with the
risk of a subsequent explosion. The vapor/gas is heavier than air and will spread along
the ground. Vapors may accumulate in low or confined areas or travel a considerable
distance to a source of ignition and flash back.
No information available
|
| Explosion Limits | |
| Upper | No data available |
| Lower |
No data available
spray to keep fire-exposed containers cool.Promptly isolate the scene by removing all persons from the vicinity of the incident if
there is a fire. No action shall be taken involving any personal risk or without suitable
training. Move containers from fire area if this can be done without risk. Use water
spray to keep fire-exposed containers cool.
|
| Sensitivity to Mechanical Impact | No information available |
| Sensitivity to Static Discharge | No information available |
| Specific Hazards Arising from the Chemical | Non-combustible. Thermal decomposition can lead to release of irritating gases and vapors. Keep product and empty containeraway from heat and sources of ignition. |
| Hazardous Combustion Products | Hydrogen halides. Sodium oxides. |
| Protective Equipment and Precautions for Firefighters | As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) andfull protective gear. |

| Personal Precautions | Ensure adequate ventilation. Use personal protective equipment as required. Avoiddust formation. |
| Environmental Precautions | Do not flush into surface water or sanitary sewer system. |
| Methods for Containment and Clean Up | Sweep up and shovel into suitable containers for disposal. Keep in suitable, closedcontainers for disposal. |

| Handling | Ensure adequate ventilation. Wear personal protective equipment/face protection. Avoiddust formation. Do not get in eyes, on skin, or on clothing. Avoid ingestion andinhalation. |
| Storage | Keep container tightly closed. Keep in a dry, cool and well-ventilated place. Storeunderaninert atmosphere. Keep container tightly closed in a dry and well-ventilated place. Protect from moisture. Incompatible Materials. Strong oxidizing agents. Strong acids. Halogens. |

| Exposure Guidelines | This product does not contain any hazardous materials with occupational exposurelimitsestablished by the region specific regulatory bodies. |
| Engineering Measures | Ensure adequate ventilation, especially in confined areas. Ensure that eyewashstationsand safety showers are close to the workstation location. |
Personal Protective Equipment
| Eye/face Protection | Wear appropriate protective eyeglasses or chemical safety goggles as describedbyOSHA's eye and face protection regulations in 29 CFR 1910.133 or EuropeanStandard EN166. |
| Skin and body protection | Wear appropriate protective gloves and clothing to prevent skin exposure. |
| Respiratory Protection | Follow the OSHA respirator regulations found in 29 CFR 1910.134 or EuropeanStandardEN 149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. |
| Recommended Filter type | Particle filter |
| Hygiene Measures | Handle in accordance with good industrial hygiene and safety practice |

Information on basic physical and chemical properties
| Physical state | Powder Solid |
| Appearance | White |
| Odor | No information available |
| Odor Threshold | No information available |
| pH | 5-8.8 5% aq. solution |
| Melting Point/Range | 755 °C / 1391 °F |
| Boiling Point/Range | 1390 °C / 2534 °F @ 760 mmHg |
| Flash Point | No information available |
| Evaporation Rate | Not applicable |
| Flammability (solid,gas) | No information available |
| Flammability or explosive limits | |
| Upper | No data available |
| Lower | No data available |
| Vapor Pressure | No information available |
| Vapor Density | Not applicable |
| Specific Gravity | No information available |
| Solubility | 905 g/L (20°C) |
| Partition coefficient; n-octanol/water | No data available |
| Autoignition Temperature | No information available |
| Decomposition Temperature | 800 °C |
| Viscosity | Not applicable |
| Molecular Formula | Br Na |
| Molecular Weight | 102.89 |

| Reactive Hazard | None known, based on information available |
| Stability | Hygroscopic. |
| Conditions to Avoid | To avoid thermal decomposition, do not overheat. Incompatible products. Exposuretomoistair or water. |
| Incompatible Materials | Strong oxidizing agents, Strong acids, Halogens |
| Hazardous Decomposition Products |
Hydrogen halides, Sodium oxides
|
| Hazardous Polymerization | Hazardous polymerization does not occur. |
| Hazardous Reactions | None under normal processing. |

| Component | LD50 Oral | LD50 Dermal | LC50 Inhalation |
| Sodium bromide | LD50 = 3500 mg/kg ( Rat ) | >2000 mg/kg ( Rabbit ) | Not listed |
| Irritation | No information available |
| Sensitization | No information available |
| Carcinogenicity | The table below indicates whether each agency has listed any ingredient as acarcinogen. |
| Component | CAS No | IARC | NTP | ACGIH | OSHA | Mexico |
| Sodium bromide | 7647-15-6 | Not listed | Not listed | Not listed | Not listed | Not listed |
| Mutagenic Effects | Not mutagenic in AMES Test |
| Reproductive Effects | No information available. |
| Developmental Effects | No information available. |
| Teratogenicity | No information available. |
| STOT - single exposure | Central nervous system (CNS) |
| STOT - repeated exposure |
None known
|
| Aspiration hazard | No information available |
| Symptoms / effects,both acute and delayed | No information available |
| Endocrine Disruptor Information | No information available |
| Other Adverse Effects | The toxicological properties have not been fully investigated. |

| Ecotoxicity | Contains a substance which is:. Very toxic to aquatic organisms. The product contains following substances which arehazardousfor the environment. |
| Component | CAS No | Freshwater Algae | Microtox | Water Flea |
| Sodium bromide |
EC50: 5800 - 24000 mg/L,
96h (Scenedesmus
pannonicus)
|
LC50: > 1000 mg/L, 96h
static (Oncorhynchus
mykiss)
LC50: 24000 - 96000 mg/L,
96h flow-through (Oryzias
latipes)
LC50: = 24000 mg/L, 96h
semi-static (Oryzias latipes)
LC50: 16000 - 24000 mg/L,
96h flow-through (Poecilia
reticulata)
LC50: = 16000 mg/L, 96h
semi-static (Poecilia
reticulata)
LC50: 0.054 - 0.081 mg/L,
96h flow-through
(Oncorhynchus mykiss)
LC50: > 1000 mg/L, 96h
static (Lepomis macrochirus)
LC50: 15614 - 17428 mg/L,
96h static (Pimephales
promelas)
|
- | EC50: 5700 - 10800 mg/L,48h Static (Daphnia magna)EC50: 5800 - 48000 mg/L,48h (Daphnia magna) |
| Persistence and Degradability | Soluble in water Persistence is unlikely based on information available. |
| Bioaccumulation/ Accumulation | No information available. |
| Mobility | Will likely be mobile in the environment due to its water solubility |

| Waste Disposal Methods | Chemical waste generators must determine whether a discarded chemical is classifiedasahazardous waste. Chemical waste generators must also consult local, regional, andnational hazardous waste regulations to ensure complete and accurate classification. |

| DOT | Not regulated |
| TDG | Not regulated |
| IATA | Not regulated |
| IMDG/IMO | Not regulated |

United States of America Inventory
| Component | CAS No | TSCA |
TSCA Inventory notification -
Active-Inactive |
TSCA - EPA RegulatoryFlags |
| Sodium bromide | 7647-15-6 | X | ACTIVE | - |
|
TSCA - Per 40 CFR 751, Regulation of Certain Chemical
Substances & Mixtures, Under TSCA Section 6(h) (PBT)
|
Not applicable |
| TSCA 12(b) - Notices of Export | Not applicable |
| International Inventories | Canada (DSL/NDSL), Europe (EINECS/ELINCS/NLP), Philippines (PICCS), Japan (ENCS), Japan (ISHL), Australia (AICS), China (IECSC), Korea(KECL). |
| Component | CAS No | DSL | NDSL | EINECS | PICCS | ENCS | ISHL | AICS | IECSC | KECL |
| Sodium bromide | 7647-15-6 | X | - | 231-599-9 | X | X | X | X | X | KE-31368 |
U.S. Federal Regulations
| SARA 313 | Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA). This product does not containanychemicals which are subject to the reporting requirements of the Act and Title 40 of the Code of Federal Regulations, Part 372 |
| SARA 311/312 Hazard Categories | Should this product meet EPCRA 311/312 Tier reporting criteria at 40 CFR 370, refer to Section 2 of this SDS for appropriateclassifications. |
| CWA (Clean Water Act) | Not applicable |
| Clean Air Act | Not applicable |
| OSHA - Occupational Safety and Health Administration | Not applicable |
| CERCLA | This material, as supplied, does not contain any substances regulated as hazardous substances under the ComprehensiveEnvironmental Response Compensation and Liability Act (CERCLA) (40 CFR 302) or the Superfund Amendments andReauthorization Act (SARA) (40 CFR 355). There may be specific reporting requirements at the local, regional, or statelevel pertaining to releases of this material. |
| California Proposition 65 | This product does not contain any Proposition 65 chemicals. |
| U.S. State Right-to-Know Regulations | Not applicable |
| U.S. Department of Transportation | |
| Reportable Quantity (RQ) | N |
| DOT Marine Pollutant | N |
| DOT Severe Marine Pollutant | N |
| U.S. Department of Homeland Security | This product does not contain any DHS chemicals |
| Other International Regulations | |
| Mexico - Grade | No information available |
| Authorisation/Restrictions according to EU REACH | Not applicable |
| Component | CAS No |
REACH (1907/2006) -
Annex XIV - Substances
Subject to Authorization
|
REACH (1907/2006) -
Annex XVII - Restrictions
on Certain Dangerous
Substances
|
REACH Regulation (EC1907/2006) article 59 -Candidate List of
Substances of Very High Concern (SVHC)
|
| Sodium bromide | 7647-15-6 | - | - | - |
Safety, health and environmental regulations/legislation specific for the substance or mixture
| Component | CAS No | OECD HPV |
Persistent Organic
Pollutant
|
Ozone Depletion Potential |
Restriction of
Hazardous Substances (RoHS)
|
| Sodium bromide | 7647-15-6 | Listed | Not applicable | Not applicable | Not applicable |
Other International Regulations
| Component | CAS No |
Seveso III Directive
(2012/18/EC) -
Qualifying Quantities
for Major Accident
Notification
|
Seveso III Directive
(2012/18/EC) -
Qualifying Quantities
for Safety Report
Requirements
|
Rotterdam Convention (PIC) | Basel Convention(Hazardous Waste) |
| Sodium bromide | 7647-15-6 | Not applicable | Not applicable | Not applicable | Not applicable |

| Other Information |
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and weassume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International has been advised of the possibility of such damages. DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable. |